Objective: Investigators studied an emergency department (ED) physical chart system and identified inconsistent, small font labeling; a single-color scheme; and an absence of human factors engineering (HFE) cues. A case study and description of the methodology with which surrogate measures of chart-related patient safety were studied and subsequently used to reduce latent hazards are presented.
Background: Medical records present a challenge to patient safety in EDs. Application of HFE can improve specific aspects of existing medical chart organization systems as they pertain to patient safety in acute care environments.
Methods: During 10 random audits over 5 consecutive days (573 data points), 56 (9.8%) chart binders (range 0.0-23%) were found to be either misplaced or improperly positioned relative to other chart binders; 12 (21%) were in the critical care area. HFE principles were applied to develop an experimental chart binder system with alternating color-based chart groupings, simple and prominent identifiers, and embedded visual cues.
Results: Post-intervention audits revealed significant reductions in chart binder location problems overall (p < 0.01), for Urgent Care A and B pods (6.4% to 1.2%; p < 0.05), Fast Track C pod (19.3% to 0.0%; p < 0.05) and Behavioral/Substance Abuse D pod (15.7% to 0.0%; p < 0.05) areas of the ED. The critical care room area did not display an improvement (11.4% to 13.2%; p = 0.40).
Conclusions: Application of HFE methods may aid the development, assessment, and modification of acute care clinical environments through evidence-based design methodologies and contribute to safe patient care delivery.