Disorders of iron metabolism affect over a billion people worldwide. The circulating peptide hormone hepcidin, the central regulator of iron distribution in mammals, holds great diagnostic potential for an array of iron-associated disorders, including iron loading (β-thalassemia), iron overload (hereditary hemochromatosis), and iron deficiency diseases. We describe a novel high-throughput matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry assay for quantification of hepcidin in human plasma. This assay involves enrichment using a functionalized MALDI chip, a novel solvent-detergent precipitation buffer, and quantification using a stable isotope labeled internal standard. The linear range of hepcidin in plasma was 1-120 nM, with a low limit of quantification (LOQ) (1 nM), high accuracy (<15% relative error (RE)), and high precision (intraday average 5.52-18.48% coefficient of variation (CV) and interday 9.32-14.83% CV). The assay showed strong correlation with an established hepcidin immunoassay (Spearman; R(2) = 0.839 n = 93 ethylenediaminetetraacetic acid (EDTA) plasma). A collection of normal healthy pediatric samples (range 3.8-32.5 ng/mL; mean 12.9 ng/mL; n = 119) showed significant differences from an adult collection (range 1.8-48.7 ng/mL; mean 16.1 ng/mL; n = 95; P = 0.0096). We discuss these preliminary reference ranges and correlations with additional parameters in light of the utility and limitations of hepcidin measurements as a stand-alone diagnostic and as a tool for therapeutic intervention.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac2020905DOI Listing

Publication Analysis

Top Keywords

high-throughput matrix-assisted
8
matrix-assisted laser
8
laser desorption
8
desorption ionization
8
ionization time-of-flight
8
mass spectrometry
8
quantification hepcidin
8
hepcidin human
8
human plasma
8
iron
5

Similar Publications

Advanced tissue technologies of blood-brain barrier organoids as high throughput toxicity readouts in drug development.

Heliyon

January 2025

Roche Pharma Research and Early Development (pRED), Roche Innovation Center Basel, F. Hoffmann-La Roche Ltd, Grenzacherstrasse 124, 4070, Basel, Switzerland.

Recent advancements in engineering Complex models (CIVMs) such as Blood-brain barrier (BBB) organoids offer promising platforms for preclinical drug testing. However, their application in drug development, and especially for the regulatory purposes of toxicity assessment, requires robust and reproducible techniques. Here, we developed an adapted set of orthogonal image-based tissue methods including hematoxylin and eosin staining (HE), immunohistochemistry (IHC), multiplex immunofluorescence (mIF), and Matrix Assisted Laser Desorption/Ionization Mass Spectrometry Imaging (MALDI-MSI) to validate CIVMs for drug toxicity assessments.

View Article and Find Full Text PDF

MALDI-TOF mass spectrometric immunoassay of multiple tumor biomarkers for non-small cell lung cancer screening.

Talanta

January 2025

State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China. Electronic address:

Cancer biomarkers have been facing some issues such as poor accuracy and low sensitivity in the early diagnosis of tumors. Utilizing biotin-labelled peptide as a mass tag (MT), this work proposes a high-throughput biosensing strategy for matrix-assisted laser desorption/ionization-time of flight mass spectrometric (MALDI-TOF-MS) immunoassay of multiple lung cancer biomarkers. Due to little required dosage, satisfied stability, high sensitivity and accuracy, this method can achieve off-site centralized signal detection after on-site sample incubation.

View Article and Find Full Text PDF

Single-Cell Peptide Profiling to Distinguish Stickleback Ecotypes with Divergent Breeding Behavior.

J Proteome Res

January 2025

Department of Chemistry and the Beckman Institute for Advanced Science and Technology, University of Illinois Urbana─Champaign, Urbana, Illinois 61801, United States.

Variation in parenting behavior is widespread across the animal kingdom, both within and between species. There are two ecotypes of the three-spined stickleback fish () that exhibit dramatic differences in their paternal behavior. Males of the common ecotype are highly attentive fathers, tending to young from eggs to fry, while males of the white ecotype desert offspring as eggs.

View Article and Find Full Text PDF

Integrating Chemoselective Labeling and Laser-Cleavable Mass Tagging for Determination of Sialic Acids in Glycoconjugates.

Anal Chem

January 2025

Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis of Zhejiang Province, Institute of Mass Spectrometry, School of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, China.

Sialic acids are the terminal units of glycans in glycoproteins or glycolipids. The determination of sialic acids in glycoconjugates is crucial since they regulate essential biological functions and have a significant nutritional value. To achieve a specific and high-throughput in situ determination of sialic acids in glycoconjugates, a laser-desorption/ionization mass spectrometry (LDI-MS)-based strategy is reported by integrating chemoselective labeling and laser-cleavable mass tagging.

View Article and Find Full Text PDF

Establishment of MS LOC platform and its pilot application in clinical lipidomics.

Talanta

April 2025

Zhejiang Key Laboratory of Multi-omics Precision Diagnosis and Treatment of Liver Diseases, Department of General Surgery, Sir Run-Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; School of Medicine, Shaoxing University, Shaoxing, Zhejiang, 312000, China; School of Basic Medical Sciences and Forensic Medicine, Hangzhou Medical College, Hangzhou, Zhejiang, 310000, China. Electronic address:

Lipidomics has demonstrated significant potential for disease diagnosis and prediction. The development and optimization of a robust mass spectrometry (MS) platform for lipidome analysis is critically important, as it can facilitate biomarker discovery, cohort testing, and performance evaluation in clinical lipidomics studies. In this work, we developed a high-throughput and reliable platform, termed MS Lab on a Chip (MS LOC), which integrates the MetArray chip, an automated lipidomics pretreatment protocol, and the reflectron matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) instrument.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!