This study examined the interactive fluid dynamics between a cavopulmonary assist device and univentricular Fontan circulation. We conducted two-dimensional particle image velocimetry measurements on an idealized total cavopulmonary connection (TCPC) with an axial pump prototype intravascularly inserted into the inferior vena cava (IVC) and then in the IVC and the superior vena cava (SVC) for a dual-pump support case. The glass model of the TCPC consisted of rigid vessels having a diameter of 13.4 mm and a one-diameter vessel offset at the TCPC junction. Fluid velocity profiles were examined at a cardiac output of 3 L/min and SVC and IVC flow ratios of 30/70%, 40/60%, and 50/50% and pump rotational speeds from 3000 to 9000 rpm. In addition, cardiac outputs of 5 and 7 L/min were also examined. As compared to the flow profile with the pump present, the measured velocity field demonstrated the presence of rotational (i.e., out of plane) motion, which forced the higher-velocity regions toward the periphery of the vessel. As a result, few flow vortices were captured in the image plane downstream of the pump in the TCPC junction. However, the velocity profiles for all cases demonstrated the expected shunting preference of IVC flow toward the right pulmonary artery. Furthermore, the inclusion of the pump provided a pressure rise of 3 to 9 mm Hg, which would be sufficient to relieve systemic hypertension in Fontan patients with circulatory dysfunction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1525-1594.2011.01345.x | DOI Listing |
Eur Radiol
January 2025
Department of Information Technology, Uppsala University, 75237, Uppsala, Sweden.
Objectives: The aim is to assess the feasibility and accuracy of a novel quantitative ultrasound (US) method based on global speed-of-sound (g-SoS) measurement using conventional US machines, for breast density assessment in comparison to mammographic ACR (m-ACR) categories.
Materials And Methods: In a prospective study, g-SoS was assessed in the upper-outer breast quadrant of 100 women, with 92 of them also having m-ACR assessed by two radiologists across the entire breast. For g-SoS, ultrasonic waves were transmitted from varying transducer locations and the image misalignments between these were then related analytically to breast SoS.
Foods
January 2025
Graduate School of Science and Technology, Niigata University, 8050 Ikarashi 2 nocho, Nishi-ku, Niigata 950-2181, Japan.
High-pressure treatment was utilized in this study to produce high-quality, reduced-sodium pork gels with desirable texture and sensory properties, addressing the challenge of maintaining quality in low-sodium meat products to meet health-conscious consumer demands. High-pressure treatment applied within the range of 150-200 MPa significantly reduced cooking loss while maintaining moisture content and provided an ideal network structure for reduced-sodium pork gels. High-pressure treatment at up to 100-200 MPa, in combination with added sodium chloride and sodium polyphosphate, was evaluated for its effects on gel texture, with results indicating that high-pressure treatment significantly improved breaking stress (increased by 10.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
School of Engineering and Innovation, The Open University, Milton Keynes MK7 6AA, UK.
A simple pore microstructure of parallel, identical, and inclined smooth-walled slits in a rigid solid, for which prediction of its geometrical and acoustic properties is straightforward, can yield useful sound absorption. This microstructure should be relatively amenable to 3D printing. Discrepancies between measurements and predictions of normal incidence sound absorption spectra of 3D printed vertical and slanted slit pore samples have been attributed to the rough surfaces of the slit walls and uneven slit cross-sections perpendicular to the printing direction.
View Article and Find Full Text PDFJ Comput Assist Tomogr
January 2025
GE HealthCare, Waukesha, WI.
Objective: Patient positioning during clinical practice can be challenging, and mispositioning leads to a change in CT number. CT number fluctuation was assessed in single-energy (SE) EID, dual-energy (DE) EID, and deep silicon photon-counting detector (PCD) CT over water-equivalent diameter (WED) with different mispositions.
Methods: A phantom containing five clinically relevant inserts (Mercury Phantom, Gammex) was scanned on a clinical EID CT and a deep silicon PCD CT prototype at vertical positions of 0, 4, 8, and 12 cm.
Objective: The aim of this study is to test the feasibility of a custom 3D-printed guide for performing a minimally invasive cochleostomy for cochlear implantation.
Study Design: Prospective performance study.
Setting: Secondary care.