A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Feasibility of postmortem device acquisition for potential reuse in underserved nations. | LitMetric

Objectives: The purpose of the present study was to examine the feasibility and efficacy of a program to acquire devices with adequate battery life from crematories and funeral homes for potential reutilization in underserved nations.

Background: There exists a great health-care disparity between the industrialized world and underserved nations--specifically in the frequency of pacemaker implantation.

Methods: Flyers were mailed to all 1057 members of the Michigan Funeral Directors Association providing information to download a consent-for-explant form and request a postage-paid envelope from www.myheartyourheart.org in order to send explanted devices. Donated devices from funeral homes and crematories nationwide were also collected from World Medical Relief. Adequate battery life was defined as ≥75% or ≥4 years of estimated longevity.

Results: A total of 3176 devices (65% pacemakers, 21% implantable cardioverter-defibrillators [ICDs], 12% biventricular ICDs, and 3% biventricular pacemakers) were donated to the reutilization program. Five hundred fifty devices (21%; 95% confidence interval [CI] 19.4-22.6%) were found to have an acceptable battery life for reutilization. Among these devices, 313 were pacemakers (17.9%; 95% CI 16.1-19.8%), 118 were ICDs (17.9%; 95% CI 15.1-21.1%), 112 were biventricular ICDs (30.3%; 95% CI 25.6-35.2%), and 7 were biventricular pacemakers (17.3%; 95% CI 16.0-18.7%).

Conclusions: Approximately 21% of donated devices and 30% of donated biventricular ICDs possess an adequate battery life for potential reuse. Device donations from funeral homes and crematories appear to be a potential resource for device reutilization for those in need in underserved nations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2011.09.067DOI Listing

Publication Analysis

Top Keywords

battery life
16
adequate battery
12
funeral homes
12
biventricular icds
12
potential reuse
8
underserved nations
8
reutilization underserved
8
donated devices
8
homes crematories
8
biventricular pacemakers
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!