Distensibility testing of the esophagus.

Ann N Y Acad Sci

Department of Medical Physics & Clinical Engineering and Trinity College, Adelaide & Meath Hospital, Dublin, Ireland.

Published: September 2011

The following contains commentaries on distensibility testing using the functional lumen imaging probe (FLIP); the use of the distention test of the esophageal body in the clinic diagnosis of noncardiac chest pain; the functional lumen imaging in gastroesophageal reflux disease-impaired esophagogastric junction; a multimodal pain model for the esophagus; the rationale for distensibility testing; and further developments in standardized distension protocols.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1749-6632.2011.06069.xDOI Listing

Publication Analysis

Top Keywords

distensibility testing
12
functional lumen
8
lumen imaging
8
testing esophagus
4
esophagus commentaries
4
commentaries distensibility
4
testing functional
4
imaging probe
4
probe flip
4
flip distention
4

Similar Publications

Tacrine is a centrally active non-competitive reversible acetylcholinesterase inhibitor. It also exerts antagonising activity against -methyl-D-aspartate receptors. Tacrine was approved for the treatment of Alzheimer's disease in 1993, but was withdrawn from clinical use in 2013 because of its hepatotoxicity and gastrointestinal side effects.

View Article and Find Full Text PDF

Racial Differences in the Levator Ani Muscle and Levator Hiatus in Individuals of Reproductive Age.

Am J Obstet Gynecol

December 2024

Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA. Electronic address:

Background: Most studies on pelvic floor muscle morphology (dimensions, shape) and its relationship with patient characteristic risk factors of pelvic floor dysfunction (demographics, medical history) have largely pertained to White individuals with vaginas. There is a need to establish normative data on pelvic floor muscle anatomy and identify morphological differences in racially diverse cohorts that may play a role in racial differences in the prevalence and pathophysiology of pelvic floor dysfunction.

Objective: (s): This study aimed to compare levator ani muscle thickness and levator hiatal morphology and their association with patient characteristics, between asymptomatic Black and White women-identifying individuals with a vagina of reproductive age.

View Article and Find Full Text PDF

Sjögren's syndrome (SS) is a chronic autoimmune disorder primarily affecting exocrine glands, leading to symptoms such as dry mouth and dry eyes. While SS can occur as a primary condition, it may overlap with other autoimmune diseases, complicating management. Autoimmune hepatitis (AIH), a liver disorder characterized by elevated serum globulins and liver-specific autoantibodies, can co-occur with SS, although this overlap is rare.

View Article and Find Full Text PDF

Behçet's Disease (BD) is a multisystem inflammatory disorder that can lead to severe vascular complications, including Budd-Chiari Syndrome (BCS), a rare but life-threatening condition characterized by hepatic vein obstruction. The co-occurrence of BD and inherited thrombophilia, such as Factor V Leiden mutation, significantly increases the risk of thrombosis, complicating the clinical management of affected individuals. In this case, a 16-year-old female initially presented with nonspecific symptoms of generalized fatigue and bone pain, which later progressed to abdominal distension and significant hepatosplenomegaly.

View Article and Find Full Text PDF

The ability for snakes to ingest large prey (macrostomy) is a widespread, derived trait that involves distending the skin during ingestion and metabolic upregulation during digestion. The material behavior of the skin must accommodate significant stretch associated with a large prey bolus, but data remain sparse for how the material properties of snake skin vary: longitudinally within an individual, after ingesting large prey and among species. To test whether these three factors affected the mechanical properties of snake skin, we quantified uniaxial stresses and strains in circumferential loops of skin from the neck, mid-body and tail of fasted and recently fed Boa constrictor.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!