The paper presents data on the cultivation of human dermal fibroblasts and rabbit mesenchymal stromal cells on two types of porous titanium implants, i.e., those with irregular pores formed by pressed titanium particles and those with regular pores formed by the cohesion of one-size titanium particles inside the implant. The goal of this study was to determine what type of titanium implant porosity ensured its strongest interaction with cells. Cells were cultivated on implants for 7 days. During this period, they formed a confluent monolayer on the implant surface. Cells grown on titanium implants were monitored by scanning electron microscopy. Fibroblasts interaction with implants depended on the implant porosity structure. On implants with irregular pores cells were more spread. On implants with regular pores fibroblasts enveloped particles and were only occasionally bound with neighboring particles by small outgrowths. There was no tight interaction of particles inside the implant. In implants formed by pressed particles, cells grow not only on surface, but also in the depth of the implant. Thus, we suppose that a tighter interaction of cells with the titanium implant and, supposedly, tissues with the implant in the organism will take place in the variant when the implant structure is formed by pressed titanium particles, i.e., cellular interaction was observed inside the implant. In implants with irregular pores, cells grew both on the surface and in the depth. Thus, cells exhibited more adequate interactions with irregular pore titanium implants in vitro and hopefully the same interaction will be true in tissues after the implantation of the prosthesis into the organism.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3178890 | PMC |
http://dx.doi.org/10.1134/S1990519X10060088 | DOI Listing |
Int Microbiol
January 2025
Department of Orthopedics and Traumatology, Ankara University School of Medicine, Ankara, Turkey.
Purpose: The most frequently used surgical procedures for periprosthetic joint infections (PJIs) are debridement, antibiotics, and implant retention (DAIR), as well as single- or two-stage revision arthroplasty. The choice of surgery is made depending on the full maturation of the biofilm layer. The purpose of this study was to evaluate the biofilm formation and microbial growth using common PJI-causing agents and compare its development on the implant surface.
View Article and Find Full Text PDFVet Res Commun
January 2025
Veterinary Teaching Hospital, Complutense University of Madrid, Avda. Puerta de Hierro s/n, Madrid, 28040, Spain.
This case report describes the reconstruction of a rostral maxillary defect by two custom-made titanium implants following a rostral partial maxillectomy for treatment of squamous cell carcinoma (SCC) in a seven-year-old dog. An incisional biopsy and CT scan were performed to establish the diagnosis, to plan possible surgery, and to assess the margins of the tumour. The patient had no radiographic signs of metastasis at the time of diagnosis.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Department of Fixed Prosthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt.
Background: Anatomically formed healing abutments were suggested in literature to address many of the issues associated with immediate posterior implant insertion such as large extraction sockets that are extremely hard to seal without reflecting the mucoperiosteal flap, extraction sockets anatomy that are not suitable for regular healing abutment placement, and potentially high occlusal stresses when planning a temporary implant supported prothesis to improve the conditioning of supra implant tissue architecture and the emergence profile of the implant supported restorations.
Purpose: To clinically evaluate the peri-implant soft tissue profile of single posterior implant retained restorations and to assess patient related outcomes of the implant restorations that were conditioned immediately by CAD-CAM socket sealing abutments (SSA) versus those conditioned by Titanium (Ti) standard healing abutments (SHA).
Methods: Twenty participants received twenty-two single maxillary immediate implants after flapless minimally invasive tooth extraction and 3D guided implant placement in the posterior area (premolar and molar) and allocated randomly into two groups (n = 11), the intervention group: patients received PEEK SSA and the control group: the patients received Ti SHA.
J Spine Surg
December 2024
Surgical and Orthopaedic Research Laboratories, Prince of Wales Clinical School, University of New South Wales, Sydney, AUS.
Background: Implant fixation is often the cornerstone of musculoskeletal surgical procedures performed to provide bony fixation and/or fusion. The aim of this study was to evaluate how different design features and manufacturing methods influence implant osseointegration and mechanical properties associated with fixation in a standardized model in cancellous bone of adult sheep.
Methods: We evaluated the performance of three titanium alloy implants: (A) iFuse-TORQ implant; (B) Fenestrated Sacroiliac Device; and (C) Standard Cancellous Bone Screw in the cancellous bone of the distal femur and proximal tibia in 8 sheep.
ACS Nano
January 2025
Advanced Medical Research Institute, Cheeloo College of Medicine, Shandong University, Jinan 250012, P. R. China.
Blood-contacting medical devices can easily trigger immune responses, leading to thrombosis and hyperblastosis. Constructing microtexture that provides efficient antithrombotic and rapid reendothelialization performance on complex curved surfaces remains a pressing challenge. In this work, we present a robust and regular micronano binary texture on the titanium surface, characterized by exceptional mechanical strength and precisely controlled wettability to achieve excellent hemocompatibility.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!