A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Amperometric detection of L-lactate using nitrogen-doped carbon nanotubes modified with lactate oxidase. | LitMetric

Nitrogen-doped carbon nanotubes (N-CNTs) provide a simple, robust, and unique platform for biosensing. Their catalytic activity toward the oxygen reduction reaction (ORR) and subsequent hydrogen peroxide (H(2)O(2)) disproportionation creates a sensitive electrochemical response to enzymatically generated H(2)O(2) on the N-CNT surface, eliminating the need for additional peroxidases or electron-transfer mediators. Glassy carbon electrodes were modified with 7.4 atom % N-CNTs, lactate oxidase (LOx), and a tetrabutylammonium bromide (TBABr)-modified Nafion binder. The resulting amperometric l-lactate biosensors displayed a sensitivity of 0.040 ± 0.002 A M(-1) cm(-2), a low operating potential of -0.23 V (vs Hg/Hg(2)SO(4)), a repeatability of 1.6% relative standard deviation (RSD) for 200 μM samples of lactate, a fabrication reproducibility of 5.0% (RSD), a limit of detection of 4.1 ± 1.6 μM, and a linear range of 14-325 μM. Additionally, over a 90 day period, the repeatability for 200 μM samples of lactate remained below 3.4% (RSD). Direct electron transfer was observed between the LOx redox-active center and the N-CNTs with the electroactive surface coverage determined to be 0.27 nmol cm(-2).

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac2016272DOI Listing

Publication Analysis

Top Keywords

nitrogen-doped carbon
8
carbon nanotubes
8
lactate oxidase
8
200 μm
8
μm samples
8
samples lactate
8
amperometric detection
4
detection l-lactate
4
l-lactate nitrogen-doped
4
nanotubes modified
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!