A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Forced vital capacity in patients with idiopathic pulmonary fibrosis: test properties and minimal clinically important difference. | LitMetric

Rationale: Forced vital capacity (FVC) is an established measure of pulmonary function in idiopathic pulmonary fibrosis (IPF). Evidence regarding its measurement properties and minimal clinically important difference (MCID) in this population is limited.

Objectives: To assess the reliability, validity, and responsiveness of FVC and estimate the MCID in patients with IPF.

Methods: The study population included all 1,156 randomized patients in two clinical trials of IFN-γ1b. FVC and other measures of functional status were measured at screening or baseline and 24-week intervals thereafter. Reliability was assessed based on two proximal measures of FVC, validity was assessed based on correlations between FVC and other measures of functional status, and responsiveness was assessed based on the relationship between 24-week changes in FVC and other measures of functional status. Distribution-based and anchor-based methods were used to estimate the MCID.

Measurements And Main Results: Correlation of percent-predicted FVC between measurements (mean interval, 18 d) was high (r = 0.93; P < 0.001). Correlations between FVC and other parameters were generally weak, with the strongest observed correlation between FVC and carbon monoxide diffusing capacity (r = 0.38; P < 0.001). Correlations between change in FVC and changes in other parameters were slightly stronger (range, r = 0.16-0.37; P < 0.001). Importantly, 1-year risk of death was more than twofold higher (P < 0.001) in patients with a 24-week decline in FVC between 5% and 10%. The estimated MCID was 2-6%.

Conclusions: FVC is a reliable, valid, and responsive measure of clinical status in patients with IPF, and a decline of 2-6%, although small, represents a clinically important difference.

Download full-text PDF

Source
http://dx.doi.org/10.1164/rccm.201105-0840OCDOI Listing

Publication Analysis

Top Keywords

clinically difference
12
fvc
12
fvc measures
12
measures functional
12
functional status
12
assessed based
12
forced vital
8
vital capacity
8
idiopathic pulmonary
8
pulmonary fibrosis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!