Background: We report our use of portable head computed tomography (CT) and the diagnostic yield and radiation dose from head CT in the pediatric intensive care unit (PICU).

Methods: 204 PICU patients underwent head CT during 2008-2009. Therapeutic interventions and resource intensity during CT were categorized. Severity of illness was summarized using the pediatric risk of mortality (PRISM-III) model. Estimates of patient radiation dose were based on dose measurements made in four anthropomorphic head phantoms.

Results: 242 (62%) out of 391 head CT studies were portable. New pathology was identified on 80 (40%) scans. CT findings prompted a change in management in 46 (23%) patients; 25 of these resulted in life-extending treatments and 21 had forgoing of life-sustaining treatments within 24 hours. 26 patients with PRISM score greater than 30% underwent CT; 23 (88%) of these were portable. More portable versus fixed examinations were performed in patients requiring extracorporeal membrane oxygenation, inhaled nitric oxide, high levels of positive end expiratory pressure, and those with high vasopressor scores (P < 0.05). Estimated patient dose from portable CT was 83 ± 6 mGy compared to 72 ± 5 mGy for patients imaged on a fixed scanner (P < 0.0001).

Conclusion: Two-thirds of CT scans obtained in the PICU were portable because of patients' intensity of therapy and illness severity. Portable CT showed major new pathology in greater than 1/3 and led to a change in management in 1/4 of higher acuity patients scanned. The estimated radiation dose from portable CT is within the current national guidelines.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12028-011-9627-3DOI Listing

Publication Analysis

Top Keywords

radiation dose
12
portable
9
head computed
8
computed tomography
8
diagnostic yield
8
change management
8
dose portable
8
head
6
patients
6
dose
5

Similar Publications

Alpha/beta values in pediatric medulloblastoma: implications for tailored approaches in radiation oncology.

Radiat Oncol

January 2025

Department of Radiotherapy and Radiooncology, Medical Faculty, Heinrich Heine University, Moorenstr. 5, 40225, Dusseldorf, Germany.

Background: Medulloblastoma is the most common malignant pediatric brain tumor, typically treated with normofractionated craniospinal irradiation (CSI) with an additional boost over about 6 weeks in children older than 3 years. This study investigates the sensitivity of pediatric medulloblastoma cell lines to different radiation fractionation schedules. While extensively studied in adult tumors, these ratios remain unknown in pediatric cases due to the rarity of the disease.

View Article and Find Full Text PDF

True total-body and extended axial field-of-view (AFOV) PET/CT with 1m or more of body coverage are now commercially available and dramatically increase system sensitivity over conventional AFOV PET/CT. The Siemens Biograph Vision Quadra (Quadra), with an AFOV of 106cm, potentially allows use of significantly lower administered radiopharmaceuticals as well as reduced scan times. The aim of this study was to optimise acquisition protocols for routine clinical imaging with FDG on the Quadra the prioritisation of reduced activity given physical infrastructure constraints in our facility.

View Article and Find Full Text PDF

Recent advances in oncology research have highlighted the promising synergy between low-dose radiation therapy (LDRT) and immunotherapies, with growing evidence highlighting the unique benefits of the combination. LDRT has emerged as a potent tool for stimulating the immune system, triggering systemic antitumor effects by remodeling the tumor microenvironment. Notably, LDRT demonstrates remarkable efficacy even in challenging metastatic sites such as the liver (uveal) and brain (cutaneous), particularly in advanced melanoma stages.

View Article and Find Full Text PDF

Enhancing furcation involvement classification on panoramic radiographs with vision transformers.

BMC Oral Health

January 2025

Department of Periodontics, Affiliated Hospital of Medical School, Nanjing Stomatological Hospital, Research Institute of Stomatology, Nanjing University, Nanjing, China.

Background: The severity of furcation involvement (FI) directly affected tooth prognosis and influenced treatment approaches. However, assessing, diagnosing, and treating molars with FI was complicated by anatomical and morphological variations. Cone-beam computed tomography (CBCT) enhanced diagnostic accuracy for detecting FI and measuring furcation defects.

View Article and Find Full Text PDF

Variable stressor exposure shapes fitness within and across generations.

Sci Rep

January 2025

Aquatic Ecology, Department of Biology, Lund University, Lund, Sweden.

Environmental variation has long been considered a key driver of evolutionary change, predicted to shape different strategies, such as genetic specialization, plasticity, or bet-hedging to maintain fitness. However, little evidence is available with regards to how the periodicity of stressors may impact fitness across generations. To address this gap, I conducted a reciprocal split-brood experiment using the freshwater crustacean, Daphnia magna, and an ecologically relevant environmental stressor, ultraviolet radiation (UVR).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!