Tunable multi-chamber microfluidic membrane microlenses with achromaticity over a given focal length range are demonstrated. In analogy to a fixed-focus achromatic doublet lens, the multi-lens system is based on a stack of microfluidic cavities filled with optically optimized liquids with precisely defined refractive index and Abbe number, and these are independently pneumatically actuated. The membranes separating the cavities form the refractive optical surfaces, and the curvatures as a function of pressure are calculated using a mechanical model for deformation of flexible plates. The results are combined with optical ray tracing simulations of the multi-lens system to yield chromatic aberration behavior, which is verified experimentally. A focal length tuning range of 5-40 mm and reduction in chromatic aberration of over 30% is demonstrated, limited by the availability of optical fluids.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.19.018584 | DOI Listing |
J Clin Med
December 2024
The David J Apple Center for Vision Research, Department of Ophthalmology, Heidelberg University Eye Clinic, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.
This laboratory study aims to assess the effects of misaligning different trifocal intraocular lenses (IOLs) under varying spectral and corneal spherical aberration (SA) conditions. With an IOL metrology device under monochromatic and polychromatic conditions, the following models were studied: AT ELANA 841P, AT LISA Tri 839MP, FineVision HP POD F, Acrysof IQ PanOptix, and Tecnis Synergy ZFR00V. The SA was simulated using an aberration-free and average-SA cornea.
View Article and Find Full Text PDFSci Rep
January 2025
Hannover Centre for Optical Technologies (HOT), Leibniz University Hannover, Hannover, Germany.
Hyperspectral imaging (HSI) systems acquire images with spectral information over a wide range of wavelengths but are often affected by chromatic and other optical aberrations that degrade image quality. Deconvolution algorithms can improve the spatial resolution of HSI systems, yet retrieving the point spread function (PSF) is a crucial and challenging step. To address this challenge, we have developed a method for PSF estimation in HSI systems based on computed wavefronts.
View Article and Find Full Text PDFNat Commun
January 2025
State Key Laboratory of Terahertz and Millimeter Waves, City University of Hong Kong, Hong Kong, 999077, China.
Terahertz (THz) lens constitutes a vital component in the THz system. Metasurfaces-based THz metalenses and classical bulky lenses are severely constrained by chromatic/ spherical aberration and the diffraction limit. Consequently, achromatic super-resolution THz lenses are urgently needed.
View Article and Find Full Text PDFAdv Sci (Weinh)
December 2024
Engineering Product Development, Singapore University of Technology and Design, Singapore, 487372, Singapore.
Spatially selective imaging (SSI) involves sampling a group of pixels from different positions on an encoded object to display a decoded image. Here, SSI is achieved by using off-axis cylindrical Fresnel lens arrays to decode multiple images from an encoded print of structural color pixels. Each image is optically retrieved by separately placing different "keys" (arrays of lenses in different pseudorandom configurations) over the same encoded print, and then each image is digitally reconstructed for visualization.
View Article and Find Full Text PDFFront Neurosci
December 2024
Intramural Research Program, National Institute on Drug Abuse National Institutes of Health, Baltimore, MD, United States.
Miniature fluorescence microscopes (miniscopes) are one of the most powerful and versatile tools for recording large scale neural activity in freely moving rodents with single cell resolution. Recent advances in the design of genetically encoded calcium indicators (GECIs) allow to target distinct neuronal populations with non-overlapping emission spectral profiles. However, conventional miniscopes are limited to a single excitation, single focal plane imaging, which does not allow to compensate for chromatic aberration and image from two spectrally distinct calcium indicators.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!