Purpose: The purpose of this study was to investigate the effect of set structure, in terms of repetition work:rest ratios on force, velocity, and power during jump squat training.
Methods: Twenty professional and semiprofessional rugby players performed training sessions comprising four sets of 6 repetitions of a jump squat using four different set configurations. The first involved a traditional configuration (TR) of 4 × 6 repetitions with 3 min of rest between sets, the second (C1) 4 × 6 × singles (1 repetition) with 12 s of rest between repetitions, the third (C2) 4 × 3 × doubles (2 repetitions) with 30 s of rest between pairs, and the third (C3) 4 × 2 × triples (3 repetitions) with 60 s of rest between triples. A spreadsheet for the analysis of controlled trials that calculated the P-value, and percent difference and Cohen's effect size from log-transformed data was used to investigate differences in repetition force, velocity, and power profiles among configurations.
Results: Peak power was significantly lower (P < .05) for the TR condition when compared with C1 and C3 for repetition 4, and all cluster configurations for repetitions 5 and 6. Peak velocity was significantly lower (P < .05) for the TR condition compared with C3 at repetition 4, significantly lower compared with C2 and C3 at repetition 5, and significantly lower compared with all cluster conditions for repetition 6.
Conclusions: Providing inter-repetition rest during a traditional set of six repetitions can attenuate decreases in power and velocity of movement through the set.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1123/ijspp.6.4.455 | DOI Listing |
Ultrasonics
January 2025
Medical Ultrasound Department for the Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China. Electronic address:
Shear Wave Elastography (SWE) is an imaging technique that detects shear waves generated by tissue excited by Acoustic Radiation Force (ARF), and characterizes the mechanical properties of soft tissue by analyzing the propagation velocity of shear wave. ARF induces a change in energy density through the nonlinear propagation of ultrasound waves, which drives the tissue to generate shear waves. However, the amplitude of shear waves generated by ARF is weak, and the shear waves are strongly attenuated in vivo.
View Article and Find Full Text PDFCureus
December 2024
Department of Osteopathic Principles and Practice, Nova Southeastern University Dr. Kiran C. Patel College of Osteopathic Medicine, Tampa, USA.
Both Irritable Bowel Syndrome (IBS) and Gastroesophageal Reflux Disease (GERD) pose significant healthcare burdens on the general population of America. Though first-line medications are available, concomitant burdens of polypharmacy, side effects, and inadequate control exist. Osteopathic Manipulative Treatment (OMT) is a hands-on, physical manipulation technique that offers a personalized and direct approach to modifying the body's neuromuscular and viscerosomatic activity leading to decreased symptomatic burden with minimal side effects.
View Article and Find Full Text PDFUltrasonics
January 2025
Department of Robotics and Mechatronics, AGH University of Krakow, 30-059 Krakow, Poland. Electronic address:
Ultrasound shear wave elastography (SWE) is widely used in clinical applications for non-invasive measurements of soft tissue viscoelasticity. The study of tissue viscoelasticity often involves the analysis of shear wave phase velocity dispersion curves, which show how the phase velocity varies with frequency or wavelength. In this study, we propose an alternative method to the two-dimensional Fourier transform (2D-FT) and Phase Gradient (PG) methods for shear wave phase velocity estimation.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Mechanical Engineering, Faculty of Engineering, Urmia University, Urmia, Iran.
This study investigates the nonlinear dynamics of a system with frequency-dependent stiffness using a MEMS-based capacitive inertial sensor as a case study. The sensor is positioned directly on a rotating component of a machine and consists of a microbeam clamped at both ends by fixed supports with a fixed central proof mass. The nonlinear behavior is determined by electrostatic forces, axial and bending motion coupling, and frequency-dependent stiffness.
View Article and Find Full Text PDFPLoS One
January 2025
Centre National de la Recherche Scientifique, Institut des Sciences du Mouvement, Aix-Marseille Univ, Marseille, France.
Little is known about the influence of fatigue in repeated overground sprinting on force-velocity properties in children and adolescents, while this ability to repeat sprints is important for future progress in rugby union. Sprint time decline is commonly used to assess fatigability. However, it does not provide data on biomechanical aspects of sprint performance such as maximal power, force, and velocity production.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!