Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aims: Uncertainty exists over the importance of device-detected short-duration atrial arrhythmias. Continuous atrial diagnostics, through home monitoring (HM) technology (BIOTRONIK, Berlin, Germany), provides a unique opportunity to assess frequency and quantity of atrial fibrillation (AF) episodes defined as atrial high-rate events (AHRE).
Methods And Results: Prospective data from 560 heart failure (HF) patients (age 67 ± 10 years, median ejection fraction 27%) patients with a cardiac resynchronization therapy (CRT) device capable of HM from two multi-centre studies were analysed. Atrial high-rate events burden was defined as the duration of mode switch in a 24-h period with atrial rates of >180 beats for at least 1% or total of 14 min per day. The primary endpoint was incidence of a thromboembolic (TE) event. Secondary endpoints were cardiovascular death, hospitalization because of AF, or worsening HF. Over a median 370-day follow-up AHRE occurred in 40% of patients with 11 (2%) patients developing TE complications and mortality rate of 4.3% (24 deaths, 16 with cardiovascular aetiology). Compared with patients without detected AHRE, patients with detected AHRE>3.8 h over a day were nine times more likely to develop TE complications (P= 0.006). The majority of patients (73%) did not show a temporal association with the detected atrial episode and their adverse event, with a mean interval of 46.7 ± 71.9 days (range 0-194) before the TE complication.
Conclusion: In a high-risk cohort of HF patients, device-detected atrial arrhythmias are associated with an increased incidence of TE events. A cut-off point of 3.8 h over 24 h was associated with significant increase in the event rate. Routine assessment of AHRE should be considered with other data when assessing stroke risk and considering anti-coagulation initiation and should also prompt the optimization of cardioprotective HF therapy in CRT patients.