Peri-implant bone changes following tooth extraction, immediate placement and loading of implants in the edentulous maxilla.

Clin Oral Investig

Training Center for Dental Students of KU Leuven, Sint-Jan Hospital, Ruddershove 10, 8000 Bruges, Belgium.

Published: August 2012

The aim of this study was to clinically and radiographically evaluate peri-implant bone level changes after rehabilitation of a fully edentulous maxilla by placement of six implants in either fresh extraction sites or healed edentulous ridges up till 18 months after implant placement. Twenty patients with a terminal dentition in the maxillae (11 men, 9 women) received a total of 120 OsseoSpeed implants; 118 implants could be loaded immediately of which 59 were placed in extraction sockets and 59 were placed in healed sites. Within 24 h after surgery, all patients received a chairside-assembled, fibre-reinforced temporary fixed prosthetic reconstruction in occlusion. Six months post-surgery, final screw-retained CoCr (15) or Ti (5) computer numerical control-milled and acrylic-veneered frameworks were placed directly at implant level without interposing abutments. Intraoral radiographs were taken 6 and 18 months after implant placement. Implant survival rate was 100%. Mean marginal bone level was located on average -0.35 mm below the reference point (standard deviation 0.29, range -1.20 to +0.02 mm) 18 months after loading. Whether implants were placed in healed bone sites or fresh extraction sockets did not significantly affect the bone level changes. Furthermore, the use of either CoCr or Ti at the implant level did not significantly affect marginal bone loss. Within the limits of this prospective clinical trial, results seem to indicate that immediate placement and occlusal loading of five to six implants in the edentulous maxilla can be carried out successfully. Whether or not those implants are placed in fresh extraction sockets does not seem to alter the outcome. The present data show a successful 1-year outcome of a treatment protocol involving tooth extraction immediately combined with implant placement and loading.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00784-011-0617-9DOI Listing

Publication Analysis

Top Keywords

loading implants
12
edentulous maxilla
12
bone level
12
fresh extraction
12
implant placement
12
extraction sockets
12
peri-implant bone
8
tooth extraction
8
placement loading
8
implants edentulous
8

Similar Publications

The best treatment method for reverse obliquity intertrochanteric fractures (ROIFs) is still under debate. Our team designed the modified proximal femoral nail (MPFN) specially for treating such fractures. The objective of this research was to introduce the MPFN device and compare the biomechanical properties with Proximal Femoral Nail Antirotation (PFNA) and InterTAN nail via finite element modelling.

View Article and Find Full Text PDF

Periprosthetic joint infections occur in 1-2% of all patients undergoing prosthetic joint surgeries. Although strong efforts have been made to reduce infection rates, conventional therapies like one- or two-stage revisions have failed to lower the infection rates. Cold atmospheric plasma (CAP) has shown promising results in reducing bacterial loads on surfaces.

View Article and Find Full Text PDF

Transalveolar sinus floor elevation (TSFE) is a surgical technique for the placement of dental implants in patients with reduced height of the maxillary posterior alveolar bone. This study aims to demonstrate the clinical outcomes of TSFE using the minimal invasive sinus elevation (MISE) technique in partially and totally edentulous maxillary patients. This prospective clinical study followed STROBE guidelines.

View Article and Find Full Text PDF

A comparative analysis has been carried out between three different dental materials suitable for the prostheses manufacturing. The analysis performed is based on the finite elements method (FEM) and was made to evaluate their performance under three different loading conditions. Three different materials were modeled with 3D CAD geometry, all of them suitable to be simulated by means of a linear elastic model.

View Article and Find Full Text PDF

The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!