Purpose: Here, we present a physical and psychophysical characterization of a new clinical unit (named AcSelerate) for digital radiography based on a thick a-Se layer. We also compared images acquired with and without a software filter (named CRF) developed for reducing sharpness and noise of the images and making them similar to images coming from traditional computed radiography systems.

Methods: The characterization was achieved in terms of physical figures of merit [modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE)], and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). We accomplished measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9.

Results: The system shows an excellent MTF (about 50% at the Nyquist frequency). The DQE is about 55% at 0.5 lp/mm and above 20% at the Nyquist frequency and is almost independent from exposure. The contrast-detail curves are comparable to some of the best published data for other systems devoted to imaging in general radiography. The CRF filter influences both the MTF and NPS, but it does lead to very small changes on DQE. Also the visibility of CDRAD details is basically unaltered, when the filter is activated.

Conclusions: As normally happens with detector based on direct conversion, the system presents an excellent MTF. The improved efficiency caused by the thick layer allows getting good noise characteristics and DQE results better (about 10% on average) than many of the computed radiography (CR) systems and comparable to those obtained by the best systems for digital radiography available on the market.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.3605471DOI Listing

Publication Analysis

Top Keywords

digital radiography
12
clinical unit
8
radiography based
8
based thick
8
physical psychophysical
8
psychophysical characterization
8
computed radiography
8
excellent mtf
8
nyquist frequency
8
comparable best
8

Similar Publications

Objective: To evaluate the NEXUS Chest CT ALL decision instrument (DI) in reducing unnecessary chest CT imaging in minor blunt trauma patients while preserving high sensitivity for detecting clinically meaningful injuries. Additionally, we examined the impact of delayed presentation, chronic disease, and anticoagulation/anti-aggregation medications on trauma outcomes.

Methods: This retrospective study included 853 adult minor blunt trauma patients who underwent chest CT in the emergency department (ED) of Tel-Aviv Sourasky Medical Center between 2018 and 2022.

View Article and Find Full Text PDF

Non-invasive assessment of pulmonary nodule malignancy remains a critical challenge in lung cancer diagnosis. Traditional methods often lack precision in differentiating benign from malignant nodules, particularly in the early stages. This study introduces an approach using multifractal spectrum analysis to quantitatively evaluate pulmonary nodule characteristics.

View Article and Find Full Text PDF

Background: Chest computed tomography (CT) is a valuable tool for diagnosing and predicting the severity of coronavirus disease 2019 (COVID-19) and assessing extrapulmonary organs. Reduced muscle mass and visceral fat accumulation are important features of a body composition phenotype in which obesity and muscle loss coexist, but their relationship with COVID-19 outcomes remains unclear. In this study, we aimed to investigate the association between the erector spinae muscle (ESM) to epicardial adipose tissue (EAT) ratio (ESM/EAT) on chest CT and disease severity in patients with COVID-19.

View Article and Find Full Text PDF

Pancreas divisum occurs during development when the ventral and dorsal buds of the pancreas do not fuse. It is the most common congenital anomaly of the pancreas. Patients with this condition are usually asymptomatic, but almost 25% of these patients experience recurrent pancreatitis, which may progress to chronic pancreatitis.

View Article and Find Full Text PDF

BACKGROUND Extensor pollicis longus (EPL) tendon rupture is a potential complication following distal radius fracture, typically occurring several weeks after injury. Herein, we present a rare case of acute extensor pollicis longus tendon rupture associated with a distal radius fracture. CASE REPORT A 35-year-old woman visited our hospital with a distal radius fracture.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!