The National Metrology Institute of Japan has issued a certified reference material of tunnel dust for polycyclic aromatic hydrocarbons (PAHs) and toxic element analyses. PAH certification was performed using isotope dilution mass spectrometry with deuterium-labeled PAHs as internal standards. Three extraction techniques (microwave-assisted extraction with toluene/methanol, Soxhlet extraction with toluene, and pressurized liquid extraction with toluene) were used, and the extracts were measured by gas chromatography/mass spectrometry with two different columns. For values of PAHs, 11 PAHs are provided as certified values between 0.294 and 20.3 mg/kg, and five PAHs are provided as information values. Certified values of five toxic elements (Cr, Ni, Pb, Mn, and Cd) obtained from microwave-assisted digestions and a combination of measurement techniques are also provided between 43.4 and 10.71 × 10(3) mg/kg.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-011-5399-zDOI Listing

Publication Analysis

Top Keywords

certified reference
8
reference material
8
polycyclic aromatic
8
aromatic hydrocarbons
8
toxic elements
8
tunnel dust
8
national metrology
8
metrology institute
8
institute japan
8
extraction toluene
8

Similar Publications

Objectives: Adenomatous colorectal polyps require endoscopic resection, as opposed to non-adenomatous hyperplastic colorectal polyps. This study aims to evaluate the effect of artificial intelligence (AI)-assisted differentiation of adenomatous and non-adenomatous colorectal polyps at CT colonography on radiologists' therapy management.

Materials And Methods: Five board-certified radiologists evaluated CT colonography images with colorectal polyps of all sizes and morphologies retrospectively and decided whether the depicted polyps required endoscopic resection.

View Article and Find Full Text PDF

: Reference materials are essential for ensuring the accuracy and traceability of measurements in the quality control of medicinal products. This study explores new principles for the preparation of impure materials of active pharmaceutical substances, focusing on 1-(3-benzoylphenyl)ethanone ketoprofen impurity A () as the reference material. : The reference material was synthesised from commercially available acetanilide and benzoyl chloride.

View Article and Find Full Text PDF

This study evaluated the validity and reliability of the TecnoBody D-Wall system in assessing joint range of motion (ROM) during overhead squat movements in healthy individuals, using Kinovea as a reference tool for data comparison. A total of 29 participants (16 males, 13 females) with a mean age of 28.41 ± 6.

View Article and Find Full Text PDF

A rapid and efficient ultrasound-assisted extraction (UAE) procedure followed by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of 14 rare earth elements (REEs) (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu), along with yttrium (Y) and scandium (Sc), in coffee samples. The method was validated using certified reference material (NIST SRM 1547), recovery tests at four fortification levels, and comparisons with microwave-assisted digestion (MAD). Excellent accuracy and precision were achieved, with recovery rates ranging from 80.

View Article and Find Full Text PDF

The influence of positive and negative intraoperative feedback in laparoscopic simulation in pediatric urology training.

J Pediatr Urol

January 2025

Department of Pediatric Surgery and Urology, National Reference Center for Rare Urinary Tract Malformations (CRMR MARVU), ERN eUROGEN Accredited Center, Robert-Debré University Hospital, APHP, GHU North, Health Simulation Department, iLumens, Université Paris Cité, Paris, France; UMR INSERM 1141 NEURODEV, Paris, France. Electronic address:

Background And Objective: This study aimed to explore the impact of positive or negative feedback on the performance of trainees in pediatric urology during simulation exercises in pediatric laparoscopy.

Methods: Twenty-five students enrolled in a national Pediatric Urology Laparoscopy Simulation participated in the study. They performed the Fundamentals of Laparoscopic Surgery (FLS) skills, specifically peg-transfer and intracorporeal knot-tying, in a randomized study design while receiving positive or negative feedback from an attending pediatric urologist.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!