Purpose: Both between-session and within-session repeatability were determined for measurement of corneal thickness with the following techniques: ultrasound pachymetry (UP), confocal microscopy (CS), Orbscan pachymetry (ORB), spectral oscillation interferometry (SOI), and optical coherence tomography (OCT).

Methods: The right eyes of 20 normal subjects were tested on 2 different days. For each session, 2 central corneal thickness measurements were determined using the ConfoScan 3 microscope, the Orbscan system, and the Stratus OCT system; 5 measurements were found with the Sonogage ultrasound pachymeter; and between 2 and 10 measurements were found with the SOI system.

Results: This study showed that SOI had the best repeatability, whereas CS had the worst repeatability for both within-session and between-session repeatability. Based on 95% limits of agreement (LoA), the within-session repeatability can be ranked as: (1) SOI; (2) UP; (3) OCT; (4) Orbscan pachymetry; and (5) CS. SOI had a bias of 0.13 and 95% LoA of -1.07 to 1.33, whereas UP had a bias of -0.98 and 95% LoA of -7.35 to 5.40. The between-session repeatability of the instruments can be ranked as: (1) SOI; (2) OCT; (3) UP; (4) Orbscan pachymetry; and (5) CS. Of the optical methods, SOI had the best repeatability with a bias of 1.26 and 95% LoA of -6.14 to 8.66, followed by OCT with a bias of 0.75 and 95% LoA of -16.22 to 17.27.

Conclusions: Of the 4 instruments that are commercially available, the UP was the most repeatable for within sessions, and the OCT was the most repeatable for between sessions.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0b013e3182152051DOI Listing

Publication Analysis

Top Keywords

95% loa
16
corneal thickness
12
orbscan pachymetry
12
central corneal
8
thickness measurements
8
within-session repeatability
8
soi best
8
best repeatability
8
between-session repeatability
8
ranked soi
8

Similar Publications

Background: The aim of the present study was to establish a predictive model to predict the peritoneal cancer index (PCI) preoperatively in patients with pseudomyxoma peritonei (PMP).

Methods: A total of 372 PMP patients were consecutively included from a prospective follow-up database between 1 June 2013 and 1 June 2023. Nine potential variables, namely, gender, age, Barthel Index (BAI), hemoglobin (Hb), albumin (Alb), D-dimer, carcinoembryonic antigen (CEA), carbohydrate antigen 125 (CA 125), and CA 19-9, were estimated using multiple linear regression (MLR) analysis with a stepwise selection procedure.

View Article and Find Full Text PDF

Background: We investigated the consistency and accuracy of the Index of Consciousness (IoC) and the Bispectral Index (BIS) in monitoring the sedative effect of ciprofol during the induction of general anesthesia. There is extensive literature that reports good consistency and correlations between the IoC1 and the BIS in reflecting the sedation levels induced by propofol and sevoflurane but not by ciprofol.

Objective: The aim was to compare the consistency and accuracy of the IoC and BIS in monitoring the sedative effect of ciprofol during the induction of general anesthesia.

View Article and Find Full Text PDF

Background: Continuous glucose monitors (CGMs) are used to characterize postprandial glucose responses and provide personalized dietary advice to minimize glucose excursions. The efficacy of such advice depends on reliable glucose responses.

Objectives: To explore within-subject variability of CGM responses to duplicate presented meals in an inpatient setting.

View Article and Find Full Text PDF

Background: Monitoring core temperature is important for patients under anesthesia. Esophageal and pulmonary artery blood temperatures can be used for measuring core temperature during general anesthesia. However, these methods pose challenges, especially when the placement of an esophageal thermometer and pulmonary artery catheter (PAC) is either impractical or not the preferred approach.

View Article and Find Full Text PDF

Validity and Reliability of the Videoconference-Based Berg Balance Scale in Stroke Survivors: The Tele-Berg Balance Scale.

J Neurol Phys Ther

December 2024

Department of Physical Therapy, Motor Control Laboratory (LADECOM), Centre of Healthy and Sport Sciences, University of Santa Catarina State, Florianópolis, Santa Catarina, Brazil.

Background And Purpose: Telerehabilitation represents an alternative for individuals who have difficulty accessing services to receive care. Therefore, telerehabilitation measures must be studied for their reliability and validity. This study evaluated the validity and reliability of the videoconference-based Berg Balance Scale assessment in stroke survivors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!