Background: The standard interpretation of perfusion imaging is based on the assessment of relative perfusion distribution. The limitations of that approach have been recognized in patients with multivessel disease and endothelial dysfunction. To date, however, no large clinical studies have investigated the value of measuring quantitative blood flow and compared that with relative uptake.

Methods And Results: One hundred four patients with moderate (30%-70%) pretest likelihood of coronary artery disease (CAD) underwent PET imaging during adenosine stress using (15)O-water and dynamic imaging. Absolute myocardial blood flow was calculated from which both standard relative myocardial perfusion images and images scaled to a known absolute scale were produced. The patients and the regions then were classified as normal or abnormal and compared against the reference of conventional angiography with fractional flow reserve. In patient-based analysis, the positive predictive value, negative predictive value, and accuracy of absolute perfusion in the detection of any obstructive CAD were 86%, 97%, and 92%, respectively, with absolute quantification. The corresponding values with relative analysis were 61%, 83%, and 73%, respectively. In region-based analysis, the receiver operating characteristic curves confirmed that the absolute quantification was superior to relative assessment. In particular, the specificity and positive predictive value were low using just relative differences in flow. Only 9 of 24 patients with 3-vessel disease were correctly assessed using relative analysis.

Conclusions: The measurement of myocardial blood flow in absolute terms has a significant impact on the interpretation of myocardial perfusion. As expected, multivessel disease is more accurately detected.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCIMAGING.110.960732DOI Listing

Publication Analysis

Top Keywords

absolute quantification
12
myocardial perfusion
12
blood flow
12
coronary artery
8
artery disease
8
multivessel disease
8
myocardial blood
8
positive predictive
8
relative
7
perfusion
6

Similar Publications

Development of a droplet digital PCR method for the detection of .

Pract Lab Med

January 2025

Department of Clinical Laboratory Medicine, Guangdong Provincial Key Laboratory of Major Obstetric Diseases, Guangdong Provincial Clinical Research Center for Obstetrics and Gynecology, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510150, China.

Background: Human infection with is mainly manifested as non-gonococcal urethritis, where it can lead to cervicitis, premature rupture of membranes and abortion in women, as well as infertility in males, which becomes a major problem in clinical diagnosis and treatment. At present, real-time fluorescence quantitative PCR and culture are the two main methods for detecting UU. The real-time fluorescence quantitative PCR method is cumbersome and cannot accomplish absolute quantification on nucleic acids, while the cultivation method has limitations such as low sensitivity and being time-consuming.

View Article and Find Full Text PDF

Background: Leptomeningeal metastasis (LM) is a devastating complication of cancer that is difficult to treat. Thus, early diagnosis is essential for LM patients. However, cerebrospinal fluid (CSF) cytology has low sensitivity, and imaging approaches are ineffective.

View Article and Find Full Text PDF

High-throughput screening to identify endocrine disruptors: Contribution of low-resolution tandem MS and high-resolution MS.

Anal Chim Acta

February 2025

Univ Rennes, Inserm, EHESP, Irset (Institut de recherche en santé, environnement et travail) - UMR_S 1085, F-35000, Rennes, France.

Background: Considering the large diversity of chemicals present in the environment and the need to study their effects (alone or as mixtures), the development of high-throughput in vitro assays in line with the Replacement, Reduction, Refinement (3R) strategy is essential for chemical risk assessments.

Results: We developed a robust analytical workflow based on both low resolution tandem mass spectrometry (MS/MS) and high-resolution mass spectrometry (HRMS) to quantify 13 steroids in NCI-H295R cell culture medium, human plasma and serum. The workflow was validated by screening media from the NCI-H295R cell line exposed in dose-response experiments to 5 endocrine disruptors (EDs) such as bisphenol A, prochloraz, ketoconazole, atrazine and forskolin.

View Article and Find Full Text PDF

Albumin and γ-globulin concentrations in subcutaneous adipose tissues (SAT) have been quantified by multivariate regression based on admittance relaxation time distribution (mraRTD) under the fluctuated background of sodium electrolyte concentration. The mraRTD formulates P = Ac + Ξ (P: peak matrix of distribution function magnitude ɣP and frequency τP, c: concentration matrix of albumin cAlb, γ-globulin Gloc, and sodium electrolyte Nac, A: coefficient matrix of a multivariate regression model, and Ξ: error matrix). The mraRTD is implemented by two processes which are: 1) the training process of A through the maximum likelihood estimation of P and 2) the quantification process of cAlb, Gloc, and Nac through the model prediction.

View Article and Find Full Text PDF

Absolute bacterial biomass estimation in the human gut is crucial for understanding microbiome dynamics and host-microbe interactions. Current methods for quantifying bacterial biomass in stool, such as flow cytometry, qPCR, or spike-ins (i.e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!