An in-premise model for Legionella exposure during showering events.

Water Res

Office of Research and Development, U.S. Environmental Protection Agency, 26 West Martin Luther King Drive, Cincinnati, OH 45268, USA.

Published: November 2011

An exposure model was constructed to predict the critical Legionella densities in an engineered water system that result in infection from inhalation of aerosols containing the pathogen while showering. The model predicted the Legionella densities in the shower air, water and in-premise plumbing biofilm that might result in a deposited dose of Legionella in the alveolar region of the lungs associated with infection for a routine showering event. Processes modeled included the detachment of biofilm-associated Legionella from the in-premise plumbing biofilm during a showering event, the partitioning of the pathogen from the shower water to the air, and the inhalation and deposition of particles in the lungs. The range of predicted critical Legionella densities in the air and water was compared to the available literature. The predictions were generally within the limited set of observations for air and water, with the exception of Legionella density within in-premise plumbing biofilms, for which there remains a lack of observations for comparison. Sensitivity analysis of the predicted results to possible changes in the uncertain input parameters identified the target deposited dose associated with infections, the pathogen air-water partitioning coefficient, and the quantity of detached biofilm from in-premise pluming surfaces as important parameters for additional data collection. In addition, the critical density of free-living protozoan hosts in the biofilm required to propagate the infectious Legionella was estimated. Together, this evidence can help to identify critical conditions that might lead to infection derived from pathogens within the biofilms of any plumbing system from which humans may be exposed to aerosols.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.watres.2011.08.031DOI Listing

Publication Analysis

Top Keywords

legionella densities
12
air water
12
in-premise plumbing
12
legionella
8
critical legionella
8
plumbing biofilm
8
deposited dose
8
showering event
8
in-premise
5
water
5

Similar Publications

The incidence of waterborne disease outbreaks in the United States attributed to drinking water-associated pathogens that can cause infections in the immunocompromised DWPIs (e.g., , nontuberculous mycobacteria (NTM), and , among others) appears to be increasing.

View Article and Find Full Text PDF

High density genomic surveillance and risk profiling of clinical Listeria monocytogenes subtypes in Germany.

Genome Med

October 2024

FG11 Division of Enteropathogenic Bacteria and Legionella, Consultant Laboratory for Listeria, Robert Koch Institute, Burgstrasse 37, Wernigerode, D-38855, Germany.

Article Synopsis
  • Foodborne illnesses like listeriosis, caused by the Listeria bacteria, are a big worry for public health, especially during outbreaks.
  • Scientists collected and studied over 1800 Listeria samples from patients in Germany to understand how the bacteria spread and caused infections.
  • They found that many infection clusters lasted a long time and could affect people in different regions, with some bacteria types being more harmful than others.
View Article and Find Full Text PDF

To realize the energy and resource utilization from organic solid waste, a two-phase microbial desalination cell (TPMDC) was constructed using dewatered sludge and kitchen waste as the anode substrate. The performance of electricity generation and composting efficacy was investigated, along with a comprehensive assessment of the potential health risks associated with the land use of the resulting mixed compost products. Experimental outcomes revealed a maximum open-circuit voltage of 0.

View Article and Find Full Text PDF

Vacuolar pathogens reside in membrane-bound compartments within host cells. Maintaining the integrity of this compartment is paramount to bacterial survival and replication as it protects against certain host surveillance mechanisms that function to eradicate invading pathogens. Preserving this compartment during bacterial replication requires expansion of the vacuole membrane to accommodate the increasing number of bacteria, and yet, how this is accomplished remains largely unknown.

View Article and Find Full Text PDF

Increases in phosphate availability in drinking water distribution systems (DWDSs) from the use of phosphate-based corrosion control strategies may result in nutrient and microbial community composition shifts in the DWDS. This study assessed the year-long impacts of full-scale DWDS orthophosphate addition on both the microbial ecology and density of drinking-water-associated pathogens that infect the immunocompromised (DWPIs). Using 16S rRNA gene amplicon sequencing and droplet digital PCR, drinking water microbial community composition and DWPI density were examined.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!