Objective: To determine interobserver and intraobserver variability in pH-impedance interpretation between experts and accuracy of automated analysis (AA).
Study Design: Ten pediatric 24-hour pH-impedance tracings were analyzed by 10 observers from 7 world groups and with AA. Detection of gastroesophageal reflux (GER) episodes was compared between observers and AA. Intraobserver agreement was assessed in 3 observers after 3 to 5 months.
Results: Overall, 1242 liquid and mixed GER events were detected, 490 (42%) were scored by the majority of observers, yielding moderate agreement (Cohen's kappa [κ] = 0.46). Intraclass co-efficient for numbers of GER per study was 0.84 (P < .001). AA has 94% sensitivity rate and 74% specificity rate compared with majority consensus (≥6 observers). Agreement for gas GER was poor (κ = 0.11). Intraobserver agreement was κ = 0.49, κ = 0.71, and κ = 0.85 in 3 observers.
Conclusion: Interobserver agreement in combined pH-multichannel intraluminal impedance analysis in experts is moderate; only 42% of GER episodes were detected by the majority of observers. Detection of total GER numbers is more consistent. Considering these poor outcomes, AA seems favorable compared with manual analysis because of its reproducibility. However, the lower specificity rate suggests the need for refinement of AA before widespread use can be advocated.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpeds.2011.08.017 | DOI Listing |
J Perinat Med
January 2025
Perinatal Imaging Research Group, School of Clinical Medicine, Discipline of Women's Health, Faculty of Medicine, University of New South Wales, Sydney, NSW, Australia.
Objectives: Multiple techniques have been proposed for functional fetal cardiology, including pulsed-wave (PW) and tissue Doppler imaging (TDI), Myocardial Performance Index (MPI), annular plane systolic excursion (TAPSE/MAPSE) and spatiotemporal image correlation (STIC). We aimed to compare these techniques' achievability and reproducibility to determine their clinical utility for each cardiac side.
Methods: Uncomplicated pregnancies from 22 to 39 weeks were recruited and images and volumes stored for offline analysis.
J Shoulder Elbow Surg
January 2025
Department of Orthopaedic Surgery and Traumatology, UZ Gent, C. Heymanslaan 10, 9000 Gent, Belgium.
Background: Mobilization of the subscapularis muscle (SSC) is crucial for optimal access to the glenohumeral joint during anatomical total shoulder arthroplasty (ATSA). However, the ideal mobilization technique remains controversial. This study aimed to assess the impact of the lesser tuberosity C-block osteotomy, a modified lesser tuberosity osteotomy, on the postoperative subscapularis (SSC) volume following anatomical shoulder arthroplasty and compare it to the volume of the infraspinatus/teres minor.
View Article and Find Full Text PDFSci Rep
January 2025
Robotics Institute, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA.
Patient-specific templating (PST), which is a sister procedure to patient-specific instrumentation (PSI) but hospital-based, is relatively less complex and less expensive than robotics and navigation. However, there are some concerns about the PST including the process of preoperative planning, 3D printing and material, positioning of PST intraoperatively, availability, and clinical value. The purpose of this study was to validate the technical accuracy and reliability of the PST technique in the lab and to report the outcomes of clinical application.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
Subject-specific parameters in lumped hemodynamic models of the cardiovascular system can be estimated using data from experimental measurements, but the parameter estimation may be hampered by the variability in the input data. In this study, we investigate the influence of inter-sequence, intra-observer, and inter-observer variability in input parameters on estimation of subject-specific model parameters using a previously developed approach for model-based analysis of data from 4D Flow MRI acquisitions and cuff pressure measurements. The investigated parameters describe left ventricular time-varying elastance and aortic compliance.
View Article and Find Full Text PDFThe diagnostic workup of primary lymphedema includes lymphoscintigraphy, a diagnostic test that provides objective data derived from the characteristics of the lymphatic flow and the lymphatic nodes. Several empirical scoring systems have been proposed with the aim of harmonizing the procedure. Here we comment the latest one, reflecting on the relevance of these tools to make possible multicenter research, based on intraobserver and interobserver reliability with the aim to, in the long run, improve patient outcomes.