A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Improvement of the properties of mineral trioxide aggregate by mixing with hydration accelerators. | LitMetric

Introduction: Mineral trioxide aggregate (MTA) is used widely in endodontic therapy. This study examined the setting time, compressive strength, and pH of MTA mixed with several hydration accelerators (calcium chloride, low-dose citric acid, calcium lactate gluconate solution).

Methods: Group 1 (control) was obtained by mixing MTA with distilled water. In group 2, MTA containing 10% calcium chloride was mixed with distilled water. In group 3, MTA was mixed with 0.1% citric acid. In group 4, MTA was mixed with a calcium lactate gluconate solution. The setting time, compressive strength, and pH were examined.

Results: The setting time of MTA mixed with hydration accelerators was significantly shorter than that of MTA mixed with water (P < .01). In particular, replacing distilled water with a calcium lactate gluconate solution provided a significant decrease in setting time. The compressive strengths of MTA mixed with hydration accelerators were significantly lower than that of MTA mixed with water (P < .01), but those values increased with time. The pH of MTA mixed with hydration accelerators was significantly lower than that of MTA mixed with water (P < .01) but stable at a high level (pH 11-12).

Conclusions: Hydration accelerators improved the setting time of MTA. Nevertheless, more study will be needed to improve MTA without impairing its preexisting advantages.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.joen.2011.06.013DOI Listing

Publication Analysis

Top Keywords

mta mixed
36
hydration accelerators
24
setting time
20
mixed hydration
16
mta
14
time compressive
12
calcium lactate
12
lactate gluconate
12
distilled water
12
group mta
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!