The objective of this work is to design, examine and apply an eight channel transmit/receive coil array tailored for cardiac magnetic resonance imaging at 7.0 T that provides image quality suitable for clinical use, patient comfort, and ease of use. The cardiac coil array was designed to consist of a planar posterior section and a modestly curved anterior section. For radio frequency (RF) safety validation, numerical computations of the electromagnetic field (EMF) and the specific absorption rate (SAR) distribution were conducted. In vivo cardiac imaging was performed using a 2D CINE FLASH technique. For signal-to-noise ratio (SNR) assessment reconstructed images were scaled in SNR units. The parallel imaging capabilities of the coil were examined using GRAPPA and SENSE reconstruction with reduction factors of up to R=4. The assessment of the RF characteristics yielded a maximum noise correlation of 0.33. The baseline SNR advantage at 7.0 T was put to use to acquire 2D CINE images of the heart with a spatial resolution of 1 mm × 1 mm × 4 mm. The coil array supports 1D acceleration factors of up to R=3 without impairing image quality significantly. For un-accelerated 2D CINE FLASH acquisitions the results revealed an SNR of approximately 140 for the left ventricular blood pool. Blood/myocardium contrast was found to be approximately 90 for un-accelerated 2D CINE FLASH acquisitions. The proposed 8 channel cardiac transceiver surface coil has the capability to acquire high contrast, high spatial and temporal resolution in vivo images of the heart at 7.0 T.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2011.08.002DOI Listing

Publication Analysis

Top Keywords

coil array
16
cine flash
12
channel transmit/receive
8
transmit/receive coil
8
image quality
8
images heart
8
un-accelerated cine
8
flash acquisitions
8
coil
6
cardiac
5

Similar Publications

This work presents the design, fabrication, and rigorous validation of a flexible, wireless, capacitive pressure sensor for the full-range continuous monitoring of ventricular pressure. The proposed system consists of an implantable set and an external readout device; both modules were designed to form an RCL resonant circuit for passive, wireless pressure sensing and signal retrieving. Using surface micromachining and flexible electronics techniques, a two-variable capacitor array and a dual-layer planar coil were integrated into a flexible ergonomic substrate, avoiding hybrid-like connections in the implantable set.

View Article and Find Full Text PDF
Article Synopsis
  • Current research shows that there’s no effective treatment for α-synucleinopathy related to Parkinson's disease, but small molecules might help prevent harmful α-synuclein aggregation.
  • This study investigates the interaction between glycitein, an O-methylated isoflavone, and α-synuclein, revealing that glycitein forms a stable complex through non-covalent interactions, mainly hydrophobic forces.
  • Glycitein demonstrates promise as a bioactive agent by preventing toxic α-synuclein aggregates in a concentration-dependent manner, protecting cells from neurotoxicity associated with Parkinson's disease.
View Article and Find Full Text PDF

A BEM-FMM TMS Coil Designer Using MATLAB Platform.

Brain Stimul

January 2025

Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, MA, USA, 01609; Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA 02129; Department of Mathematics, Worcester Polytechnic Institute, Worcester, MA, USA, 01609.

View Article and Find Full Text PDF

Overexpression of the myeloid Src-family kinases Fgr and Hck has been linked to the development of acute myeloid leukemia (AML). Here we characterized the contribution of active forms of these kinases to AML cell cytokine dependence, inhibitor sensitivity, and AML cell engraftment in vivo. The human TF-1 erythroleukemia cell line was used as a model system as it does not express endogenous Hck or Fgr.

View Article and Find Full Text PDF

Background: Low-field open magnetic resonance imaging (MRI) systems, typically operating at magnetic field strengths below 1 Tesla, has greatly expanded the accessibility of MRI technology to meet a wide range of patient needs. However, the inherent challenges of low-field MRI, such as limited signal-to-noise ratios and limited availability of dedicated radiofrequency (RF) coils, have prompted the need for innovative coil designs that can improve imaging quality and diagnostic capabilities. In this work, we introduce a multimodal axial array resonator and its implementation in a volume coil, or referred to as a coupled stack-up volume coil, to address these challenges in low-field open MRI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!