A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Serial Doppler echocardiography and tissue Doppler imaging in the detection of elevated directly measured left atrial pressure in ambulant subjects with chronic heart failure. | LitMetric

Objectives: This study sought to determine the accuracy of Doppler echocardiography and tissue Doppler imaging (TDI) measurements in detecting elevated left atrial pressure (LAP) in ambulant subjects with chronic heart failure using directly measured LAP as the reference.

Background: Echocardiographic indexes including the ratio of transmitral to annular early diastolic velocities (E/e') may identify raised invasively measured left ventricular filling pressures when tested in cross-sectional studies in some populations. The accuracy of these indexes when measured sequentially remains untested. We determined the accuracy of Doppler echocardiography and TDI measurements in detecting elevated directly measured LAP in ambulant subjects with stable chronic heart failure.

Methods: Fifteen patients with New York Heart Association functional class II to III heart failure and a permanently implanted direct LAP monitoring device underwent serial echocardiography. Simultaneous resting mean LAP, Doppler mitral inflow, mitral annular TDI, and pulmonary venous inflow velocities were obtained on each occasion. Receiver-operator characteristic curve analysis was used to compare the accuracy of the Doppler variables to detect an elevated device LAP ≥15 and ≥20 mm Hg.

Results: The patients (13 men, mean age: 71 years, mean left ventricular ejection fraction: 32 ± 12%) underwent 60 simultaneous echocardiographic studies and LAP measurements with a median of 4 (1 to 7) studies per patient. Mean LAP was 16.9 (range 5 to 39 mm Hg) at echocardiography (n = 60). E/e' had the greatest accuracy for detection of LAP ≥15 mm Hg with an area beneath the receiver-operator characteristic curve >0.9. In comparison, area under the curve for mitral E velocity and mitral E/A were 0.77 and 0.76, respectively (p < 0.008 vs. E/e' medial and average).

Conclusions: Single and serial measurements of mitral inflow and mitral annular TDI velocities (E/e') can reliably detect raised directly measured LAP in ambulant subjects with compensated chronic heart failure. (Hemodynamically Guided Home Self-Therapy in Severe Heart Failure Patients [HOMEOSTASIS]; NCT00547729).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcmg.2011.07.004DOI Listing

Publication Analysis

Top Keywords

heart failure
20
directly measured
16
ambulant subjects
16
chronic heart
16
doppler echocardiography
12
accuracy doppler
12
lap ambulant
12
measured lap
12
lap
10
echocardiography tissue
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!