A previously healthy middle-aged lady with no prior risk factors for coronary artery disease presented with chest discomfort and ECG changes suggestive of anterolateral ST elevation myocardial infarction. She had had a stressful event prior to the onset of symptoms in that she had been caught up in a riot and had been exposed to intense mental and physical stress. She was found to have severe global left ventricular dysfunction but coronary artery disease was not discovered on coronary angiography. She was treated with antiplatelets, statins, diuretics and aldosterone antagonists. Her left ventricular function was revealed to have improved to normal as shown on echocardiography done on her follow-up 2 months after initial presentation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3028171 | PMC |
http://dx.doi.org/10.1136/bcr.12.2008.1366 | DOI Listing |
Cardiovasc Eng Technol
January 2025
Transonic Systems Inc., 34 Dutch Mill Road, Ithaca, New York, 14850, USA.
Purpose: Over time, transit time flow measurement (TTFM) has proven itself as a simple and effective tool for intra-operative evaluation of coronary artery bypass grafts (CABGs). However, metrics used to screen for possible technical error show considerable spread, preventing the definition of sharp cut-off values to distinguish between patent, questionable, and failed grafts. The simulation study presented in this paper aims to quantify this uncertainty for commonly used patency metrics, and to identify the most important physiological parameters influencing it.
View Article and Find Full Text PDFHerz
January 2025
Faculty of Medicine, Department of Cardiology, Bilecik Şeyh Edebali University, Pelitözü Mahallesi Fatih Sultan Mehmet Blv. No. 27 Merkez, Bilecik, Turkey.
Background: The aim of this study was to compare the efficacy outcomes of the traditional Judkins left and right catheters with those of the recently introduced Tiger catheter in female participants aged 65 years and older who underwent transradial coronary angiography.
Methods: A cohort of 160 female patients aged 65 and older who were scheduled for coronary angiography (CAG) were divided into two groups according to the use of Tiger (n = 80) or Judkins (n = 80) catheters for radial angiography at a ratio of 1:1, respectively. We analyzed the effectiveness of the Tiger and Judkins catheters, the incidence of catheter failure, contrast volume, CAG time, fluoroscopy time, dose-area product (in mGy/cm), and the occurrence of radial spasm.
Cardiovasc Revasc Med
December 2024
Department of Cardiology, Tel Aviv Sourasky Medical Center, affiliated with the School of Medicine, Tel Aviv University, Israel.
Background: Angina with non-obstructive coronary artery disease (ANOCA) is commonly observed in patients with stable angina undergoing coronary angiography. Current guidelines recommend non-invasive stress testing as the first step in diagnosing coronary microvascular disease (CMD). This study aims to evaluate the diagnostic value of non-invasive stress testing in patients invasively diagnosed with CMD.
View Article and Find Full Text PDFJ Mol Cell Cardiol
December 2024
A.I.Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland; Heart Centre and Gene Therapy Unit, Kuopio University Hospital, Kuopio, Finland. Electronic address:
Background: Coronary stenting operations have become the main option for the treatment of coronary heart disease. Vessel recovery after stenting has emerged as a critical factor in reducing possible complications. In this study, we evaluated the feasibility, safety and efficacy of locally administered intraluminal gene therapy delivered using a specialized infusion balloon catheter.
View Article and Find Full Text PDFClin Radiol
November 2024
Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Rd., Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China. Electronic address:
Aim: To investigate the relationship between epicardial adipose tissue (EAT) and myocardial strain and the severity of coronary artery disease (CAD), and to evaluate the predictive value of EAT parameters in early left ventricular (LV) diastolic dysfunction.
Materials And Methods: One hundred seventy patients with suspected CAD who underwent both coronary computed tomography angiography and echocardiography were enrolled in 2020. LV global strains were calculated using commercial software.