This study used a mechanical test to evaluate the flexibility of instruments from the K3 (conicity 0.04) and the ProTaper Universal systems when they were new and after 5 uses in simulated canals. Five sets of instruments of each system were tested: K3 (15, 20, 25, 30, 35, 40 and 45) and ProTaper Universal (S1, S2, F1, F2, F3, F4 and F5). Each set of instruments was used to prepare a simulated canal and the same set of instruments was used 5 times (50 canals). The number of each subgroup represented the number of uses: 0 (control), 1, 3 and 5 uses. Before and after each use, the instruments were submitted to a mechanical flexibility test performed in a Versat 502 universal testing machine. Interactions between the instrument and the number of uses were analyzed by ANOVA and Tukey's test at a 5% level of significance. Instruments from both systems presented lower flexibility after the third use compared to the flexibility obtained after uses 0 and 1 (p<0.05), and maintained the same flexibility after the fifth use. The flexibility of instruments from the K3 system decreased with the increase of diameter, irrespective of the number of uses. Among the instruments from the ProTaper Universal system, the shaping files presented greater flexibility than the finishing files. F2 and F3 were the least flexible instruments, and F4 and F5 presented flexibility values similar to those of F1.

Download full-text PDF

Source
http://dx.doi.org/10.1590/s0103-64402011000300007DOI Listing

Publication Analysis

Top Keywords

protaper universal
12
set instruments
8
instruments
7
flexibility
5
flexibility protaper
4
universal
4
universal instruments
4
instruments study
4
study mechanical
4
mechanical test
4

Similar Publications

The novel assessment to explore the cutting performance of rotary instruments using dynamic finite element analysis with failure mode.

J Endod

December 2024

Graduate Institute of Clinical Dentistry, School of Dentistry, National Taiwan University and National University Hospital, 1, Chang-de St., Taipei, 100, Taiwan; National Taiwan University Hospital, National Taiwan University, No. 1, Chang-De St., Taipei City 100, Taiwan, ROC; School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, No. 100, Shih-Chuan 1st Rd., Kaohsiung City, 80708, Taiwan, ROC. Electronic address:

Introduction: The separation of nickel-titanium endodontic instruments due to excessive torque adversely affects treatment outcomes. Previous studies have analyzed torque values under static conditions and failed to accurately simulate the dynamic conditions of instruments within root canals. This study aimed to apply a novel finite element analysis (FEA) to assess the real-time dynamic performance of nickel-titanium endodontic instruments during operation in root canals.

View Article and Find Full Text PDF

: Apical extrusion of debris can affect the success of endodontic treatments, and the specific performance of certain retreatment systems has not been studied yet. Therefore, the aim of this in vitro study was to quantitatively assess the amount of apically extruded debris produced during retreatment procedures using three rotary NiTi retreatment systems in mature non-resorbed straight roots. : Thirty extracted permanent human teeth with single straight roots were selected.

View Article and Find Full Text PDF

Statement Of The Problem: Root canal preparation with rotary files causes dentinal cracks in root canals of primary teeth affecting their longevity.

Purpose: Nickel-titanium rotary files have been widely used for root canal preparation in primary teeth. The present study compared occurrence of dentinal microcracks in root canals of extracted primary molar teeth prepared using Hedstrom (H) files, ProTaper Universal rotary files, and ProTaper Next rotary file systems.

View Article and Find Full Text PDF

Objective: The present study aimed to evaluate the effect of heat-treated nickel titanium (NiTi) files TruNatomy and XP- Endo Shaper on the major apical foramen deformation and enlargement in curved root canals using area, circularity, and Feret's diameter ratio.

Methods: Sixty mesio-buccal roots of maxillary and mandibular molars with Vertucci type II root canal were selected. The teeth were decoronated using a carborundum disc.

View Article and Find Full Text PDF

Objective: To compare the effect of syringe irrigation technique, passive ultrasonic activation technique, EDDY activation technique and Er,Cr,YSGG laser activation technique on smear layer removal in root canals .

Methods: Forty mandibular first premolars with single canal were collected from patients in Qingdao Stomatological Hospital affiliated to Qingdao University. After root canal preparation with ProTaper Universal to F3, they were randomly divided into four groups (n = 10) according to different activation irrigations for the final washing: syringe irrigation (SI), passive ultrasonic activation (PU), EDDY activation (EDDY) and Er,Cr,YSGG laser activation (YSGG).

View Article and Find Full Text PDF