Viscoelastic properties of soft gels: comparison of magnetic resonance elastography and dynamic shear testing in the shear wave regime.

Phys Med Biol

Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St Louis, MO 63130, USA.

Published: October 2011

Magnetic resonance elastography (MRE) is used to quantify the viscoelastic shear modulus, G*, of human and animal tissues. Previously, values of G* determined by MRE have been compared to values from mechanical tests performed at lower frequencies. In this study, a novel dynamic shear test (DST) was used to measure G* of a tissue-mimicking material at higher frequencies for direct comparison to MRE. A closed-form solution, including inertial effects, was used to extract G* values from DST data obtained between 20 and 200 Hz. MRE was performed using cylindrical 'phantoms' of the same material in an overlapping frequency range of 100-400 Hz. Axial vibrations of a central rod caused radially propagating shear waves in the phantom. Displacement fields were fit to a viscoelastic form of Navier's equation using a total least-squares approach to obtain local estimates of G*. DST estimates of the storage G' (Re[G*]) and loss modulus G″ (Im[G*]) for the tissue-mimicking material increased with frequency from 0.86 to 0.97 kPa (20-200 Hz, n = 16), while MRE estimates of G' increased from 1.06 to 1.15 kPa (100-400 Hz, n = 6). The loss factor (Im[G*]/Re[G*]) also increased with frequency for both test methods: 0.06-0.14 (20-200 Hz, DST) and 0.11-0.23 (100-400 Hz, MRE). Close agreement between MRE and DST results at overlapping frequencies indicates that G* can be locally estimated with MRE over a wide frequency range. Low signal-to-noise ratio, long shear wavelengths and boundary effects were found to increase residual fitting error, reinforcing the use of an error metric to assess confidence in local parameter estimates obtained by MRE.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3178746PMC
http://dx.doi.org/10.1088/0031-9155/56/19/014DOI Listing

Publication Analysis

Top Keywords

mre
9
magnetic resonance
8
resonance elastography
8
dynamic shear
8
tissue-mimicking material
8
frequency range
8
increased frequency
8
shear
6
dst
5
viscoelastic properties
4

Similar Publications

Background: Observational studies propose associations between dietary factors and multiple sclerosis (MS). However, the causal nature of these relationships remains unclear. This study aims to determine whether nutritional factors causally influence MS risk through Mendelian randomization (MR) analysis.

View Article and Find Full Text PDF

For several decades, to enhance relationship quality, marriage and relationship education (MRE) programs have focused on teaching communication skills and conflict management. However, new explanations reveal that the effectiveness of communication skills in MRE programs may largely depend on virtues. Through a randomized controlled trial (RCT), the present study examined the effectiveness of the Getting Our Hearts Right Program (GOHR; a virtue-based approach) and the Prevention and Relationship Enhancement Program (PREP; a skill-based approach).

View Article and Find Full Text PDF

The magneto-mechanical coupling of multiphase magnetorheological elastomers.

J Phys Condens Matter

January 2025

Mechanical Engineering, Virginia Tech, 635 Prices Fork Road, Blacksburg, Virginia, 24061-0131, UNITED STATES.

Magnetorheological elastomers (MREs) are soft magnetic composites that achieve tunable changes in stiffness and energy response in the presence of a magnetic field. Rigid particle composite (RC) MREs have been studied for decades for their potential applications to automotive dampers and robotic systems. Recently, magnetic fluid composite (FC) MREs have been developed which utilize magnetic fluids as inclusions to elastomers.

View Article and Find Full Text PDF

Background: The current subclassification of steatotic liver disease (SLD) relies on validated questionnaires, such as Alcohol Use Disorders Identification Test (AUDIT) and Lifetime Drinking History (LDH), which, while useful, are impractical and lack precision for their use in routine clinical practice. Phosphatidylethanol (PEth) is a quantitative, objective alcohol biomarker with high sensitivity and specificity.

Aims: To assess the diagnostic accuracy of PEth for differentiating metabolic dysfunction and alcohol-associated liver disease (MetALD) from metabolic dysfunction-associated steatotic liver disease (MASLD) in a large, population-based, prospective, multiethnic cohort of individuals with overweight or obesity.

View Article and Find Full Text PDF

ABCoRT: Retention Time Prediction for Metabolite Identification via Atom-Bond Co-Learning.

J Chem Inf Model

January 2025

School of Information Science and Engineering, Yunnan University, Kunming650091,China.

Liquid chromatography retention time (RT) prediction plays a crucial role in metabolite identification, a challenging and essential task in untargeted metabolomics. Accurate molecular representation is vital for reliable RT prediction. To address this, we propose a novel molecular representation learning framework, ABCoRT(tom-ond -learning for etention ime prediction), designed for predicting metabolite retention times.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!