A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

RERBEE: robust efficient registration via bifurcations and elongated elements applied to retinal fluorescein angiogram sequences. | LitMetric

We present RERBEE (robust efficient registration via bifurcations and elongated elements), a novel feature-based registration algorithm able to correct local deformations in high-resolution ultra-wide field-of-view (UWFV) fluorescein angiogram (FA) sequences of the retina. The algorithm is able to cope with peripheral blurring, severe occlusions, presence of retinal pathologies and the change of image content due to the perfusion of the fluorescein dye in time. We have used the computational power of a graphics processor to increase the performance of the most computationally expensive parts of the algorithm by a factor of over × 1300, enabling the algorithm to register a pair of 3900 × 3072 UWFV FA images in 5-10 min instead of the 5-7 h required using only the CPU. We demonstrate accurate results on real data with 267 image pairs from a total of 277 (96.4%) graded as correctly registered by a clinician and 10 (3.6%) graded as correctly registered with minor errors but usable for clinical purposes. Quantitative comparison with state-of-the-art intensity-based and feature-based registration methods using synthetic data is also reported. We also show some potential usage of a correctly aligned sequence for vein/artery discrimination and automatic lesion detection.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TMI.2011.2167517DOI Listing

Publication Analysis

Top Keywords

rerbee robust
8
robust efficient
8
efficient registration
8
registration bifurcations
8
bifurcations elongated
8
elongated elements
8
fluorescein angiogram
8
angiogram sequences
8
feature-based registration
8
graded correctly
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!