Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: We hypothesized that combined assessment of factors that are associated with favorable reverse remodeling after cardiac resynchronization-defibrillator therapy (CRT-D) can be used to predict clinical response to the device.
Methods And Results: The study population comprised 1761 patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT). Best-subset regression analysis was performed to identify factors associated with echocardiographic response (defined as percent reduction in left ventricular end-diastolic volume 1 year after CRT-D implantation) and to create a response score. Cox proportional hazards regression analysis was used to evaluate the CRT-D versus defibrillator-only reduction in the risk of heart failure or death by the response score. Seven factors were identified as associated with echocardiographic response to CRT-D and made up the response score (female sex, nonischemic origin, left bundle-branch block, QRS ≥150 milliseconds, prior hospitalization for heart failure, left ventricular end-diastolic volume ≥125 mL/m(2), and left atrial volume <40 mL/m(2)). Multivariate analysis showed a 13% (P<0.001) increase in the clinical benefit of CRT-D per 1-point increment in the response score (range, 0-14) and a significant direct correlation between risk reduction associated with CRT-D and response score quartiles: Patients in the first quartile did not derive a significant reduction in the risk of heart failure or death with CRT-D (hazard ratio=0.87; P=0.52); patients in the second and third quartiles derived 33% (P=0.04) and 36% (P=0.03) risk reductions, respectively; and patients in the upper quartile experienced a 69% (P<0.001) risk reduction (P for trend=0.005).
Conclusion: Combined assessment of factors associated with reverse remodeling can be used for improved selection of patients for cardiac resynchronization therapy. Clinical Trial Registration- URL: http://www.clinicaltrials.gov. Unique identifier: NCT00180271.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCULATIONAHA.110.014324 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!