Unlabelled: Failure of liver stiffness measurement (LSM) by transient elastography (TE, FibroScan) and unreliable results occur in ≈ 5% and 15% of patients, respectively, mainly due to obesity. In this multicenter study, we evaluated the feasibility and performance of the novel FibroScan XL probe in 276 patients with chronic liver disease (42% viral hepatitis, 46% nonalcoholic fatty liver disease [NAFLD]) and a body mass index (BMI) ≥ 28 kg/m(2) . Patients underwent liver biopsy and TE with the standard M and XL probes. TE failure was defined as no valid LSMs and unreliable examinations as <10 valid LSMs or an interquartile range (IQR)/LSM >30% or success rate <60%. Probe performance for diagnosing ≥ F2 fibrosis and cirrhosis (F4) versus biopsy were examined using areas under receiver operating characteristic curves (AUROC). FibroScan failure was less frequent with the XL probe than the M probe (1.1% versus 16%) and the XL probe was more often reliable (73% versus 50%; both P < 0.00005). Reliable results with the XL probe were obtained in 61% of patients in whom the M probe was unreliable. Among 178 patients with ≥ 10 valid LSMs using both probes, liver stiffness was highly correlated between probes (ρ = 0.86; P < 0.0005); however, median liver stiffness was lower using the XL probe (6.8 versus 7.8 kPa; P < 0.00005). The AUROC of the XL and M probes were similar for ≥ F2 fibrosis (0.83 versus 0.86; P = 0.19) and cirrhosis (0.94 versus 0.91; P = 0.28).
Conclusion: Compared with the M probe, the FibroScan XL probe reduces TE failure and facilitates reliable LSM in obese patients. Although the probes have comparable accuracy, lower liver stiffness cutoffs will be necessary when the XL probe is used to noninvasively assess liver fibrosis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/hep.24624 | DOI Listing |
Diagnostics (Basel)
November 2024
Department of Gastroenterology and Hepatology, New York University, New York, NY 10012, USA.
: Vibration-Controlled Transient Elastography (VCTE) with FibroScan is a non-invasive, reliable diagnostic tool for Metabolic-Dysfunction-Associated Steatotic Liver Disease (MASLD), enabling early detection and management to prevent severe liver diseases. VCTE's ease and portability suit primary care, streamlining referrals, promoting lifestyle changes, reducing costs, and benefiting underserved communities. : Studies on point-of-care VCTE were systematically reviewed, followed by meta-analysis using a random-effects model.
View Article and Find Full Text PDFClin Res Hepatol Gastroenterol
October 2024
Hepatobiliary Division, Internal Medicine Department, Cipto Mangunkusumo National General Hospital, Faculty of Medicine, Universitas Indonesia, Jl. Diponegoro No. 71, Jakarta, 10430, Indonesia. Electronic address:
Background: Oesophageal varices (EV) rupture remains one of the most severe complications of cirrhosis. As the gold standard to predict this accident, esophagogastroduodenoscopy (EGD) itself also has a weakness. Not all patients are convenient with this modality in clinical practice apart from the risk and cost burden.
View Article and Find Full Text PDFSci Rep
June 2024
Division of Gastroenterology and Hepatology, Department of Internal Medicine, Soonchunhyang University Bucheon Hospital, 170 Jomaru-ro, Bucheon, 14854, Republic of Korea.
Managing complications of liver cirrhosis such as varices needing treatment (VNT) and clinically significant portal hypertension (CSPH) demands precise and non-invasive diagnostic methods. This study assesses the efficacy of spleen stiffness measurement (SSM) using a 100-Hz probe for predicting VNT and CSPH, aiming to refine diagnostic thresholds. A retrospective analysis was conducted on 257 cirrhotic patients, comparing the diagnostic performance of SSM against traditional criteria, including Baveno VII, for predicting VNT and CSPH.
View Article and Find Full Text PDFLiver Int
May 2024
Medical Data Analytics Centre, Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, China.
Background & Aims: FibroScan® Expert 630 and FibroScan® Mini+430 are novel vibration-controlled transient elastography devices equipped with the same SmartExam software, which allows continuous measurement of controlled attenuation parameter (CAP) during the entire examination. This study aims to compare the CAP variabilities and the quantification for liver fibrosis and steatosis between the conventional FibroScan and the SmartExam-equipped machines in patients with metabolic dysfunction-associated steatotic liver disease (MASLD).
Methods: This retrospective study included 118 patients with biopsy-proven MASLD who underwent liver biopsy at two tertiary centres between 2021 and 2023.
Hepatol Int
December 2023
Department of Gastroenterology, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, No.1665, Kongjiang Road, Yangpu District, Shanghai, 200092, China.
Background And Aim: Metabolic dysfunction-associated fatty liver disease (MAFLD) is the most common chronic liver disease in adolescent and adult population. However, the epidemiologic data of MAFLD in prepubertal children remain limited. This study aimed to investigate the prevalence and incidence of MAFLD and assess the role of anthropometric parameters in identifying and predicting MAFLD in this population.