PURPOSE. Retinal nerve fiber layer (RNFL) thickness measured by optical coherence tomography (OCT) can be unreliable in the presence of a myopic tilted disc. The purpose of this study was to investigate the influence of the calculation circle location of spectral domain (SD)-OCT when measuring RNFL thickness in healthy subjects with myopic tilted disc. METHODS. Sixty-nine eyes with myopic tilted disc and no other ocular abnormalities were analyzed. In all eyes, RNFL thickness was measured twice: first, along a calculation circle determined by a built-in algorithm (referred to as circle 1) and then along a manually positioned calculation circle based on the contours of the neural canal opening (NCO) (referred to as circle 2). The mean number of clock hours below normal at the 5% level and the proportion of eyes with abnormally thin clock hours at the 5% level were compared between the two methods: RESULTS. The mean number of clock hours below normal at the 5% level was significantly lower in circle 2 (0.84 ± 1.31) than in circle 1 (1.42 ± 1.43; P < 0.05). The proportion of eyes with abnormally thin clock hours at the 5% level was significantly lower (P < 0.001) in circle 2 (42%) than in circle 1 (69.9%). CONCLUSIONS. In subjects with myopic tilted disc, RNFL thickness measurements along the calculation circle based on the contours of the NCO seem to be more comparable to the normative database of the SD-OCT than does the automatically determined scan position.

Download full-text PDF

Source
http://dx.doi.org/10.1167/iovs.11-7712DOI Listing

Publication Analysis

Top Keywords

calculation circle
20
myopic tilted
20
rnfl thickness
16
tilted disc
16
clock hours
16
circle
11
circle location
8
optical coherence
8
coherence tomography
8
retinal nerve
8

Similar Publications

The demand for extended shelf life and food safety in the food industry continues to rise. At the same time, the environmental burden of traditional plastic packaging materials is becoming increasingly serious. Therefore, in this study, an intelligent bilayer film with a pH-sensitive inner indicator film based on Artemisia Sphaerocephala Krasch.

View Article and Find Full Text PDF

The "oblique effect" refers to the reduced visual performance for stimuli presented at oblique orientations compared to those at cardinal orientations. In the cortex, neurons that respond to specific orientations are organized into orientation columns. This raises the question: Are the orientation signals in the iso-orientation columns associated with cardinal orientations the same as those in the iso-orientation columns associated with oblique orientations, and is this signal influenced by experience? To explore this, iso-orientation columns in visual area 18 were examined using optical imaging techniques.

View Article and Find Full Text PDF

With the advancement of the Internet, social media platforms have gradually become powerful in spreading crisis-related content. Identifying informative tweets associated with natural disasters is beneficial for the rescue operation. When faced with massive text data, choosing the pivotal features, reducing the calculation expense, and increasing the model classification performance is a significant challenge.

View Article and Find Full Text PDF

Background: This study aims to investigate how A1 segment asymmetry-also known as A1 dominancy-influences the development of the anterior communicating artery aneurysm (AcomA) as it affects hemodynamic conditions within the circle of Willis (COW). Using time-of-flight magnetic resonance angiography (TOF-MRA), the research introduces a novel approach to assessing shear stress in A1 segments to uncover the hemodynamic factors contributing to AcomA formation.

Method: An observational study was conducted over 6 years at a tertiary university hospital's outpatient clinic.

View Article and Find Full Text PDF

Background: Anterior glenoid bone defects significantly influence surgical outcomes in shoulder instability cases. Various measurement methods based on 3-dimensional computed tomography (3D-CT) have been developed. Recently, the simple linear formula method, which establishes a correlation between glenoid height and width, has emerged as a promising technique.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!