What is the shape of the helium trimer? A comparison with the neon and argon trimers.

J Phys Chem A

Dipartimento di Scienze Chimiche e Ambientali, Universita' dell'Insubria, Via Lucini 3, 22100 Como, Italy.

Published: October 2011

Despite its apparent simplicity and extensive theoretical investigations, the issue of what is the shape of the helium trimer is still debated in the literature. After reviewing previous conflicting interpretations of computational studies, we introduce the angle-angle distribution function as a tool to discuss in a simple way the shape of any trimer. We compute this function along with many different geometrical distributions using variational and diffusion Monte Carlo methods. We compare them with the corresponding ones for the neon and argon trimers. Our analysis shows that while Ne(3) and Ar(3) fluctuate around an equilibrium structure that is an equilateral triangle, (4)He(3) shows an extremely broad angle-angle distribution function, and all kinds of three-atom configurations must be taken into account in its description. Classifying (4)He(3) as either equilateral or linear or any other particular shape, as was done in the past, is not sensible, because in this case the intuitive notion of equilibrium structure is ill defined. Our results could help the interpretation of future experiments aimed at measuring the geometrical properties of the helium trimer.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jp206612jDOI Listing

Publication Analysis

Top Keywords

shape helium
8
neon argon
8
argon trimers
8
helium trimer
8
angle-angle distribution
8
distribution function
8
equilibrium structure
8
shape
4
helium trimer?
4
trimer? comparison
4

Similar Publications

In this paper, a highly sensitive methane (CH) sensor based on light-induced thermoelastic spectroscopy (LITES) and a T-shaped quartz tuning fork (QTF) with hydrogen (H) and helium (He) enhancement techniques are reported for the first time. The low resonant frequency self-designed T-shaped QTF was exploited for improving the energy accumulation time. H and He were utilized as surrounding gases for the T-shaped QTF to minimize energy loss, thereby enhancing the sensitivity of the LITES sensor.

View Article and Find Full Text PDF

Tailored light-matter interactions in the strong coupling regime enable the manipulation and control of quantum systems with up to unit efficiency, with applications ranging from quantum information to photochemistry. Although strong light-matter interactions are readily induced at the valence electron level using long-wavelength radiation, comparable phenomena have been only recently observed with short wavelengths, accessing highly excited multi-electron and inner-shell electron states. However, the quantum control of strong-field processes at short wavelengths has not been possible, so far, because of the lack of pulse-shaping technologies in the extreme ultraviolet (XUV) and X-ray domain.

View Article and Find Full Text PDF

Anticipatory guidance on balloons typically highlights the danger of choking on uninflated balloon fragments. One type of balloon injury that is not widely discussed is suffocation due to crawling inside a large foil helium-containing balloon. A six-year-old female presented to a community hospital emergency department (ED) after being found on the floor inside a 50-inch foil balloon in the shape of the number "7.

View Article and Find Full Text PDF
Article Synopsis
  • Ion implantation in diamonds is crucial for creating conductive microstructures and isolated photon emitters, with emission lines HR1 and HR2 observed around 536 nm and 560 nm.
  • The study involved a thorough examination of helium-related optical centers in natural single-crystal type IIa diamonds, using a 700 nm-thick layer subjected to multiple-energy helium ion implantation and subsequent annealing at various temperatures.
  • Results revealed over a dozen unique photoluminescence centers within the 530-630 nm range, emphasizing the impact of annealing on the spectra and identifying specific bands related to interstitial defects in diamonds.
View Article and Find Full Text PDF

Micro-nano-scale mechanical properties are vital for engineering and biological materials. The elastic modulus is generally measured by processing the force-indentation curves obtained by atomic force microscopy (AFM). However, the measurement precision is largely affected by tip shape, tip wear, sample morphology, and the contact model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!