A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An examination of kernite (Na2B4O6(OH)2·3H2O) using X-ray and electron spectroscopies: quantitative microanalysis of a hydrated low-Z mineral. | LitMetric

Mineral borates, the primary industrial source of boron, are found in a large variety of compositions. One such source, kernite (Na2B4O6(OH)2·3H2O), offers an array of challenges for traditional electron-probe microanalysis (EPMA)-it is hygroscopic, an electrical insulator, composed entirely of light elements, and sensitive to both low pressures and the electron beam. However, the approximate stoichiometric composition of kernite can be analyzed with careful preparation, proper selection of reference materials, and attention to the details of quantification procedures, including correction for the time dependency of the sodium X-ray signal. Moreover, a reasonable estimation of the mineral's water content can also be made by comparing the measured oxygen to the calculated stoichiometric oxygen content. X-ray diffraction, variable-pressure electron imaging, and visual inspection elucidate the structural consequences of high vacuum treatment of kernite, while Auger electron spectroscopy and X-ray photoelectron spectroscopy confirm electron beam-driven migration of sodium and oxygen out of the near-surface region (sampling depth ≈ 2 nm). These surface effects are insufficiently large to significantly affect the EPMA results (sampling depth ≈ 400 nm at 5 keV).

Download full-text PDF

Source
http://dx.doi.org/10.1017/S1431927611000602DOI Listing

Publication Analysis

Top Keywords

kernite na2b4o6oh2·3h2o
8
sampling depth
8
depth ≈
8
electron
5
examination kernite
4
x-ray
4
na2b4o6oh2·3h2o x-ray
4
x-ray electron
4
electron spectroscopies
4
spectroscopies quantitative
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!