Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: Morphometric data for the sympathetic ganglia (SG) of the upper thoracic spine was investigated to identify the exact location of the SG in order to reduce normal tissue injury in the thoracic cavity during thoracoscopic sympathectomy.
Methods: In 46 specimens from 23 formalin-fixed adult cadavers, the authors measured the shortest distance from the medial margin of the T1, T2 and T3 SG to the most prominent point and medial margin of the corresponding rib heads, and to the lateral margin of the longus colli muscle. In addition, the distance between the most prominent point of the rib head and the lateral margin of longus colli muscle and the width of each SG were measured.
Results: The shortest distance from the medial margin of the SG to the prominent point of corresponding rib head was on average 1.9 mm on T1, 4.2 mm, and 4.1 mm on T2, T3. The distance from the medial margin of the SG to the medial margin of the corresponding rib head was 4.2 mm on T1, 5.9 mm, and 6.3 mm on T2, T3. The mean distance from the medial margin of the SG to the lateral margin of the longus colli muscle was 6.7 mm on T1, 8.8 mm, 9.9 and mm on T2, T3. The mean distance between the prominent point of the rib head and the lateral margin of the longus colli muscle was 4.8 mm on T1, 4.6 mm, and 5.9 mm on T2, T3. The mean width of SG was 6.1 mm on T1, 4.1 mm, and 3.1 mm on T2, T3.
Conclusion: We present morphometric data to assist in surgical planning and the localization of the upper thoracic SG during thoracoscopic sympathectomy.