Purpose: To determine the total setup error and the required planning target volume (PTV) margin for prostate bed without image guided radiotherapy (IGRT), and to demonstrate the feasibility and dosimetric benefit of IGRT post prostatectomy using surgical clips.

Materials And Methods: Seventeen patients were treated with intensity modulated radiotherapy (IMRT) to the prostate bed with a 1cm PTV margin. Three-dimensional shifts of the surgical clips inside the prostate bed were measured with respect to the isocenter from 364 orthogonal kV image pairs, and the total setup error was calculated to determine the required PTV margin. Alternative IMRT plans using 5mm or 1cm PTV expansion were generated and compared for rectal and bladder sparing.

Results: Surgical clips were reproducibly and reliably identified. The mean (standard deviation) shifts in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP), axes were: -0.1 mm (1.7 mm), 0.6 mm (2.4 mm), and -2.1 mm (2.6 mm), respectively. The required PTV margins were calculated to be 6, 8, and 9 mm in the LR, AP, and SI axis, respectively. A PTV expansion of 5mm, compared to 1cm, significantly reduced V65 Gy to the rectum by 10%.

Conclusions: In the absence of IGRT, a non-uniform PTV margin of 6mm LR, 8mm AP, and 9 mm SI should be considered. Use of clips as fiducial markers can decrease the total setup error, enable a smaller PTV margin, and improve rectal sparing.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radonc.2011.07.024DOI Listing

Publication Analysis

Top Keywords

ptv margin
20
total setup
16
setup error
16
surgical clips
12
required ptv
12
ptv expansion
12
prostate bed
12
ptv
9
clips fiducial
8
fiducial markers
8

Similar Publications

PTV Margins in MR-guided and Beam-gated SBRT of Liver Metastases: GTV Dose Escalation Can Reduce the Required PTV.

Clin Oncol (R Coll Radiol)

December 2024

Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark; Department of Oncology, Copenhagen University Hospital - Herlev and Gentofte, Herlev, Denmark.

Aims: Determining appropriate PTV margins for SBRT of liver metastases is a non-trivial task, especially with motion management included. The widely used analytical van Herk margin recipe (van Herk et al., 2000) could break down due to (i) a low number of fractions, (ii) non-Gaussian errors, or (iii) non-homogenous dose distributions.

View Article and Find Full Text PDF

Purpose: Daily online adaptive radiation therapy (oART) opens the opportunity to treat gastric mucosa-associated lymphoid tissue (MALT) lymphoma with a reduced margin. This study reports our early experience of cone beam computed tomography (CBCT)-based daily oART treating gastric MALT lymphoma with breath-hold and reduced margins.

Methods And Materials: Ten patients were treated on a CBCT-based oART system.

View Article and Find Full Text PDF

Purpose: This study focused on reducing the margin for prostate cancer treatment using magnetic resonance imaging-guided radiotherapy by investigating the intrafractional motion of the prostate and different motion-mitigation strategies.

Methods: We retrospectively analyzed intrafractional prostate motion in 77 patients with low- to intermediate-risk prostate cancer treated with five fractions of 7.25 Gy on a 1.

View Article and Find Full Text PDF

Introduction: Prostate motion during external beam radiotherapy (EBRT) is common and typically managed using fiducial markers and cone beam CT (CBCT) scans for inter-fractional motion correction. However, real-time intra-fractional motion management is less commonly implemented. This study evaluated the extent of intra-fractional prostate motion using transperineal ultrasound (TPUS) and examined the impact of treatment time on prostate motion.

View Article and Find Full Text PDF

Purpose: To use imaging data from stereotactic MR-guided online adaptive radiotherapy (SMART) of ultracentral lung tumors (ULT) for development of a safe non-adaptive approach towards stereotactic body radiotherapy (SBRT) of ULT.

Patients And Methods: Analysis is based on 19 patients with ULT who received SMART (10 × 5.0-5.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!