An ultrasensitive electrochemical sensor for the mercuric ion via controlled assembly of SWCNTs.

Chem Commun (Camb)

Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian 350002, China.

Published: October 2011

An ultrasensitive "turn-on" electrochemical sensor for the Hg(2+) ion was proposed based on the T-Hg(2+)-T coordination chemistry and the controlled assembly of SWCNTs on the MHA/SAM-modified gold electrode.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c1cc12699gDOI Listing

Publication Analysis

Top Keywords

electrochemical sensor
8
controlled assembly
8
assembly swcnts
8
ultrasensitive electrochemical
4
sensor mercuric
4
mercuric ion
4
ion controlled
4
swcnts ultrasensitive
4
ultrasensitive "turn-on"
4
"turn-on" electrochemical
4

Similar Publications

This study reports on the development of a highly sensitive non-enzymatic electrochemical sensor based on a two-dimensional TiCT/MWCNT-OH nanocomposite for the detection of paraoxon-based pesticide. The synergistic effect between the TiCT nanosheet and the functionalized multi-walled carbon nanotubes enhanced the sensor's conductivity and catalytic activity. The nanocomposite demonstrates superior electrochemical and electroanalytical performance compared to the pristine TiCT and MWCNT-OH in detecting paraoxon-ethyl in fruit samples (green and red grapes), with a linear response range from 0.

View Article and Find Full Text PDF

AI-optimized electrochemical aptasensors are transforming diagnostic testing by offering high sensitivity, selectivity, and rapid response times. Leveraging data-driven AI techniques, these sensors provide a non-invasive, cost-effective alternative to traditional methods, with applications in detecting molecular biomarkers for neurodegenerative diseases, cancer, and coronavirus. The performance metrics outlined in the comparative table illustrate the significant advancements enabled by AI integration.

View Article and Find Full Text PDF

The development of a print-at-home, low-cost, and miniaturized paper-based cell with 3D-printed electrodes using a 3D-printing pen and a bespoke conductive filament for detecting capsaicin in hot sauce is reported herein. The material cost of producing each electrode was less than £0.01.

View Article and Find Full Text PDF

A wearable antifouling electrochemical sensor integrated with an antimicrobial microneedle array for uric acid detection in interstitial fluid.

Anal Chim Acta

February 2025

Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science & Technology, Qingdao, 266042, China. Electronic address:

Wearable microneedle array (MNA) based electrochemical sensors have gained increasing attention for their capability to analyze biomarkers in the interstitial fluid (ISF), enabling noninvasive, continuous monitoring of health parameters. However, challenges such as nonspecific adsorption of biomolecules on the sensor surfaces and the risk of infection at the microneedle penetration sites hinder their practical application. Herein, a wearable dual-layer microneedle patch was prepared to overcome these issues by integrating an antimicrobial microneedle layer with an antifouling sensing layer.

View Article and Find Full Text PDF

Enhanced simultaneous voltammetric detection of lead, copper, and mercury using a MIL-101(Cr)-(COOH)@MWCNTs modified glassy carbon electrode.

Anal Chim Acta

February 2025

Chemistry Department, Faculty of Science, Ain-Shams University, Cairo, 11566, Egypt; Department of Chemistry, Faculty of Science, Galala University, New Galala City, Suez, Egypt. Electronic address:

Background: Electrochemical methods, particularly those utilizing sensors, offer distinct advantages over classical analytical methods. They are cost-effective, compatible with mass fabrication, suitable for remote sensing, and can be designed as handheld analyzers. In this context, MIL-101(Cr)-(COOH)₂@MWCNTs was utilized for the first time as a modifier for GCE for the sensitive voltammetric detection of Pb(II), Cu(II), and Hg(II).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!