We applied the C-MAC videolaryngoscope in 52 consecutive patients who were found to have an unexpected Cormack and Lehane grade-3 (n = 49) and grade-4 (n = 3) laryngeal view with the Macintosh laryngoscope. The glottic view improved in 49 (94%) patients using the C-MAC. Tracheal intubation was successful in 49 of 52 patients (94%). In one patient, tracheal intubation failed using the C-MAC despite the presence of a Cormack and Lehane grade-2. These results suggest that the C-MAC videolaryngoscope has a role as a rescue device in cases of an initially difficult laryngeal view.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1365-2044.2011.06872.xDOI Listing

Publication Analysis

Top Keywords

glottic view
8
view macintosh
8
c-mac videolaryngoscope
8
cormack lehane
8
laryngeal view
8
tracheal intubation
8
performance c-mac
4
c-mac video
4
video laryngoscope
4
patients
4

Similar Publications

Background: The Neonatal Resuscitation Program recommends direct laryngoscopy (DL) as the primary method for neonatal intubation. Video laryngoscopy (VL) is suggested as an option, particularly for training novice operators or for intubating infants with difficult airways. The programme outlines specific steps for intubation, including managing the external environment and techniques for visualising key anatomical landmarks.

View Article and Find Full Text PDF

Objectives: Several devices have been developed to improve head and neck surgery. 3D exoscopes provide surgeons a viable alternative to microscopes. We propose our setting for transoral exoscopic oropharyngeal (TOEOS) and transoral exoscopic laryngeal surgery (TOELS).

View Article and Find Full Text PDF

Comparison of neutral and sniffing position for ease of endotracheal intubation using Airtraq optical laryngoscope-A randomized trial.

J Anaesthesiol Clin Pharmacol

August 2024

Department of Anesthesia and Critical Care, Pt. B. D. Sharma PGIMS, Rohtak, Haryana, India.

Background: Traditionally, the sniffing position has been considered a standard head and neck position during direct laryngoscopy. The perfect head and neck position for video laryngoscopy has yet not been described. Hence, we planned the present study to compare the neutral and sniffing position for ease of intubation using Airtraq.

View Article and Find Full Text PDF

Background: The Laryngeal Mask Airway Vision Mask (LMA VM) is a supraglottic airway device (SAD) with a vision guidance system. The ideal head and neck position for direct laryngoscopy is known, but the ideal position for placing a LMA is not. The objective of this study is to evaluate and compare the optimal position for placement of a video laryngeal mask airway.

View Article and Find Full Text PDF

Background: In emergency settings, difficult intubations often occur unexpectedly despite pre-intubation assessments. Traditional glottic view scoring systems for direct laryngoscope may not apply to video laryngoscopy. With video laryngoscopy, the vertical location of the glottis on the monitor can be clearly defined.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!