A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cross-sectional sample of peripheral refraction in four meridians in myopes and emmetropes. | LitMetric

Cross-sectional sample of peripheral refraction in four meridians in myopes and emmetropes.

Invest Ophthalmol Vis Sci

Bradford School of Optometry and Vision Science, University of Bradford, Bradford, United Kingdom.

Published: September 2011

Purpose: The study of peripheral refractive error is of growing interest as degradation of the retinal image quality in the periphery is known to affect central refractive error development and ocular shape in animal models. The purpose of this study was to measure peripheral refraction across the horizontal, vertical, and two oblique meridians in a group of myopic and emmetropic adults and to investigate retinal asymmetry in the human retina.

Methods: Thirty-one myopes (spherical equivalent between -2.00 and -9.62 D) and 20 emmetropes (spherical equivalent between -0.50 and +0.50 D) with astigmatism less than -0.75 D, participated in the project. Noncycloplegic peripheral refraction measurements were captured with an autorefractor (NVision K-5001; Shin-Nippon, Tokyo, Japan) at the fovea and up to 30° eccentricity in the horizontal, vertical, and two oblique meridians in 10° steps. RPR was calculated by subtracting the foveal spherical equivalent refraction from that obtained at each eccentric location.

Results: Along all measured meridians, myopic eyes showed a relative hyperopic shift in the periphery, with the superior-temporal portion of the retina exhibiting the smallest shift. Emmetropic eyes, however, exhibited a relatively consistent refractive profile across all meridians and eccentricities, confirming a spherical retinal shape for this group. In addition, off-axis astigmatism increased with eccentricity in all meridians.

Conclusions: These results suggest that the myopic eye tends toward an ellipsoid shape, rather than the globular shape of an emmetropic eye.

Download full-text PDF

Source
http://dx.doi.org/10.1167/iovs.11-7635DOI Listing

Publication Analysis

Top Keywords

peripheral refraction
12
spherical equivalent
12
purpose study
8
refractive error
8
horizontal vertical
8
vertical oblique
8
oblique meridians
8
meridians
5
cross-sectional sample
4
peripheral
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!