The study whose results are presented here aimed at identifying free-living protozoa (FLP) and conditions favoring the growth of these organisms and cultivable Legionella spp. in drinking water supplies in a tropical region. Treated and distributed water (±30°C) of the water supplies of three Caribbean islands were sampled and investigated with molecular techniques, based on the 18S rRNA gene. The protozoan host Hartmannella vermiformis and cultivable Legionella pneumophila were observed in all three supplies. Operational taxonomic units (OTUs) with the highest similarity to the potential or candidate hosts Acanthamoeba spp., Echinamoeba exundans, E. thermarum, and an Neoparamoeba sp. were detected as well. In total, 59 OTUs of FLP were identified. The estimated protozoan richness did not differ significantly between the three supplies. In supply CA-1, the concentration of H. vermiformis correlated with the concentration of Legionella spp. and clones related to Amoebozoa predominated (82%) in the protozoan community. These observations, the low turbidity (<0.2 nephelometric turbidity units [NTU]), and the varying ATP concentrations (1 to 12 ng liter(-1)) suggest that biofilms promoted protozoan growth in this supply. Ciliophora represented 25% of the protozoan OTUs in supply CA-2 with elevated ATP concentrations (maximum, 55 ng liter(-1)) correlating with turbidity (maximum, 62 NTU) caused by corroding iron pipes. Cercozoan types represented 70% of the protozoan clones in supply CA-3 with ATP concentrations of <1 ng liter(-1) and turbidity of <0.5 NTU in most samples of distributed water. The absence of H. vermiformis in most samples from supply CA-3 suggests that growth of this protozoan is limited at ATP concentrations of <1 ng liter(-1).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3194851 | PMC |
http://dx.doi.org/10.1128/AEM.05575-11 | DOI Listing |
Microorganisms
October 2024
Legionella Reference Laboratory, National Centre for Microbiology, Instituto de Salud Carlos III, 28220 Majadahonda, Spain.
Two sporadic cases of legionellosis occurring in consecutive years were confirmed by positive antigenuria to serogroup 1 in individuals with limited mobility who were confined to their homes. Both cases had a history of using ultrasonic humidifiers and of low exposure to other possible sources of infection. This study was conducted through an expanded epidemiological survey and home inspection.
View Article and Find Full Text PDFMicrobiol Spectr
November 2024
Centre National de Référence des Légionelles, Institut des Agents Infectieux, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, Lyon, France.
Unlabelled: recovery from pulmonary samples is challenging due to the lack of a specific medium and the abundance of overgrown respiratory flora. This study aimed to compare the amoeba plate test (APT), an amoebic coculture with , with the axenic culture to recover from pulmonary samples. serial dilutions ( = 15 strains from seven species, concentrations ranging: 10-10 CFU/mL) in water and spiked overgrown sputa ( = 8) were simultaneously plated on agar with amoebic monolayer (APT) and without (control).
View Article and Find Full Text PDFChemosphere
October 2024
China National Rice Research Institute, Chinese Academy of Agricultural Sciences, Hangzhou, 311400, China. Electronic address:
Reuse of municipal-treated wastewater for agricultural irrigation is becoming increasingly prevalent due to growing demand and decline in freshwater supplies. However, the microbial contamination profile, including antibiotic resistance genes (ARGs), virulence factors (VFs), and human bacterial pathogens (HBPs) in agricultural soil irrigated with municipal-treated wastewater for paddy cultivation, was unknown. Here, metagenomic analysis was applied to provide a systematic insight into the resistome, VFs and HBPs in paddy soils irrigated with municipal-treated wastewater.
View Article and Find Full Text PDFInt J Hyg Environ Health
January 2025
Institute for the Transformation of the Energy System, West Coast University of Applied Sciences, Markt 18, 25746, Heide, Germany.
During the storage and distribution of water in buildings, the excessive growth of pathogens can deteriorate the quality of drinking water. This study aims to investigate the factors influencing this growth and propose technical measures for prevention. The analysis is based on an empirical data set comprising 1361 samples from 204 domestic premise plumbing systems.
View Article and Find Full Text PDFSci Total Environ
November 2024
Department of Occupational and Environmental Health, Epidemiology, Bavarian Health and Food Safety Authority, Munich, Germany; Institute and Clinic for Occupational, Social and Environmental Medicine, University Hospital, LMU Munich, Munich, Germany.
To date, in many countries the only legally valid method for evaporative cooling system (ECS) monitoring is the culture method. However, a duration of up to 14 days and a risk of underestimation of Legionella concentrations are seen as limitations of cultivation methods. Rapid cultivation-independent methods are an important step towards a more practicable monitoring of ECS to quickly control interventions if elevated concentrations of Legionella are found.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!