Background And Purpose: To investigate the effect of an endorectal balloon (ERB) on anal wall (Awall) and rectal wall (Rwall) doses in high-dose post-prostatectomy intensity-modulated radiotherapy (IMRT).
Materials And Methods: For 20 patients, referred for salvage IMRT after prostatectomy for prostate cancer, two planning CT-scans were performed: one with and one without an air-filled ERB. A planning target volume (PTV) was defined, using international guidelines. Furthermore, the Awall and Rwall were delineated. In both the scans, IMRT plans were generated with a prescribed dose of 70 Gy. The mean dose (D(mean)), maximum dose, minimum dose, and volumes exposed to doses ranging from ≥ 20 to ≥ 70 Gy (V(20)-V(70)) to the Awall and Rwall were calculated. Finally, inner Rwall surface areas exposed to doses ranging from ≥ 20 to ≥ 70 Gy (A(20)-A(70)) were calculated. Dose-parameters were compared between plans with and without ERB.
Results: All Awall parameters, except V(70), were significantly reduced by the ERB with an overall D(mean) reduction of 6 Gy. Absolute reductions in dose-volume parameters varied from 5% to 11%. Significantly reduced Rwall V(30), V(40), and A(40) were observed with ERB, irrespective of the target volume size.
Conclusion: ERB application significantly reduces Awall and to a lesser degree Rwall doses in high-dose post-prostatectomy IMRT.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.radonc.2011.07.019 | DOI Listing |
J Radiosurg SBRT
January 2024
Department of Radiation Oncology, Tokyo-Edogawa Cancer Centre, Edogawa Hospital.
Purpose: Despite the efficacy of endorectal balloon (ERB) in reducing rectal radiation dose, the effectiveness of upper rectal fixation remains to be evaluated. The purpose of this study was to evaluate the impact of ERB on upper rectal fixation in patients diagnosed with localized prostate cancer.
Materials: Cine MRI was performed in 46 patients with localized prostate cancer to assess the stability of the anterior rectal wall with and without ERB by calculating the standard deviation of the normalized signal intensity at the level of the midgland or the seminal vesicle.
J Comput Assist Tomogr
May 2024
Department of Urology, Oregon Health and Science University, Portland, OR.
We describe early ex vivo proof-of-concept testing of a novel system composed of a disposable endorectal coil and converging multichannel needle guide with a reusable clamp stand, embedded electronics, and baseplate to allow for endorectal magnetic resonance (MR) imaging and in-bore MRI-targeted biopsy of the prostate as a single integrated procedure. Using prostate phantoms imaged with standard T 2 -weighted sequences in a Siemens 3T Prisma MR scanner, we measured the signal-to-noise ratio in successive 1-cm distances from the novel coil and from a commercially available inflatable balloon coil and measured the lateral and longitudinal deviation of the tip of a deployed MR compatible needle from the intended target point. Signal-to-noise ratio obtained with the novel system was significantly better than the inflatable balloon coil at each of five 1-cm intervals, with a mean improvement of 78% ( P < 0.
View Article and Find Full Text PDFZhonghua Wei Chang Wai Ke Za Zhi
June 2023
Department of Colorectal Surgery, the Characteristic Medical Center of PLA Rocket Force, Beijing 100088, China.
Intersphincteric resection (ISR) has been performed as an ultimate sphincter-sparing strategy in selected patients with low rectal cancer. Accumulating evidence suggests that ISR may be an interesting alternative to abdominoperineal resection to avoid a permanent stoma without compromising oncological outcomes. However, bowel dysfunction is a most common consequence of ISR not to be neglected.
View Article and Find Full Text PDFMed Phys
July 2023
Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA.
Background: Deep learning auto-segmentation (DLAS) models have been adopted in the clinic; however, they suffer from performance deterioration owing to the clinical practice variability. Some commercial DLAS software provide an incremental retraining function that enables users to train a custom model using their institutional data to account for clinical practice variability.
Purpose: This study was performed to evaluate and implement the commercial DLAS software with the incremental retraining function for definitive treatment of patients with prostate cancer in a multi-user environment.
Curr Oncol
January 2023
Department of Particle Therapy, University Hospital Essen, West German Proton Therapy Centre Essen (WPE), West German Cancer Center (WTZ), 45147 Essen, Germany.
Background: The aim of this study is to examine the dosimetric influence of endorectal balloons (ERB) on rectal sparing in prostate cancer patients with implanted hydrogel rectum spacers treated with dose-escalated or hypofractionated intensity-modulated proton beam therapy (IMPT).
Methods: Ten patients with localized prostate cancer included in the ProRegPros study and treated at our center were investigated. All patients underwent placement of hydrogel rectum spacers before planning.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!