Background: Aortic arch replacement is a complicated and high risk procedure. There have been many advances over recent years. We review the changes in our unit's techniques and outcomes over the past 22 years.
Methods: Data were collated from databases and medical records for all patients who underwent aortic arch replacement surgery from January 1989 to December 2010. The patients were divided into two groups - Group A (1989-2005) and Group B (2006-2010). Data were analysed to compare early and late series patients' outcomes. Logistic regression was used to identify variables that predicted mortality.
Results: Seventy-five eligible patients (56 males; mean age: 57.5 years; Group A: 40, Group B 35) were identified. There were great changes in the technique and the methods of cerebral protection. The overall mortality rate was 30.7% - Group A: 50% and Group B: 8.6% (p<0.001). Overall permanent neurological dysfunction was 23.7% - Group A: 40% and Group B: 11.8% (p=0.012). Cardiovascular disease and circulatory arrest time were significant predictors of mortality.
Conclusions: Increased experience and volume and advances in techniques over 22 years have resulted in major improvements in outcomes for patients having aortic arch replacement, allowing the procedure to be performed with greatly improved outcomes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.hlc.2011.07.009 | DOI Listing |
Acad Radiol
January 2025
Medical Image Processing Group, 602 Goddard building, 3710 Hamilton Walk, Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104 (M.L., M.A., J.K.U., Y.T., C.W., N.P., S.M., D.A.T.). Electronic address:
Rationale And Objectives: Cardiovascular toxicity is a well-known complication of thoracic radiation therapy (RT), leading to increased morbidity and mortality, but existing techniques to predict cardiovascular toxicity have limitations. Predictive biomarkers of cardiovascular toxicity may help to maximize patient outcomes.
Methods: The machine learning optimal biomarker (OBM) method was employed to predict development of cardiotoxicity (based on serial echocardiographic measurements of left ventricular ejection fraction and longitudinal strain) from computed tomography (CT) images in patients with thoracic malignancy undergoing RT.
Int J Surg
January 2025
Department of Cardiovascular Surgery, Xijing Hospital, Xi'an, Shaanxi, China.
Background: The impact of aortic arch (AA) morphology on the management of the procedural details and the clinical outcomes of the transfemoral artery (TF)-transcatheter aortic valve replacement (TAVR) has not been evaluated. The goal of this study was to evaluate the AA morphology of patients who had TF-TAVR using an artificial intelligence algorithm and then to evaluate its predictive value for clinical outcomes.
Materials And Methods: A total of 1480 consecutive patients undergoing TF-TAVR using a new-generation transcatheter heart valve at 12 institutes were included in this retrospective study.
J Am Coll Surg
January 2025
University of Florida Health, Division of Cardiovascular Surgery, Department of Surgery, Gainesville, Florida USA.
Background: The purpose of this study is to evaluate the clinical outcomes of patients undergoing a simpler (hemiarch) vs complex (zone 2 arch) aortic repair for acute type A aortic dissection (TAAD).
Methods: Adults (≥18 years) who underwent hemiarch or zone 2 arch repair for acute, hyperacute, or acute on chronic TAAD at a single institution between January 2018 and April 2024 were reviewed. Disabling stroke was defined as modified Rankin scale ≥4.
Innovations (Phila)
December 2024
Department of Neurosciences and Rehabilitation, Cardiac Surgery Unit, University of Ferrara, Italy.
Objective: Both the en bloc island technique and the branched graft technique (BGT) present advantages but also limitations in aortic arch surgery. Here is the first presentation of an innovative prosthesis for aortic arch replacement, conceived to overcome the disadvantages of both techniques.
Methods: The novel ISLAND graft is a tubular Dacron or hybrid prosthesis with an additional extended Dacron graft ("bubble") on the superior aspect, for en bloc island graft anastomosis.
Radiol Case Rep
March 2025
Division of Maternal Fetal Medicine, Department of Obstetrics and Gynecology, State University of New York (SUNY), Downstate Health Sciences University, Brooklyn, NY, USA.
Extensive congenital pulmonary airway malformation (CPAM) of the left fetal lung and associated marked dextroposition of the fetal heart were noted at 21 weeks' gestation. The right fetal lung appeared compressed with the cardiomediastinal shift angle measuring approximately 20 degrees. Potential subsequent right pulmonary hypoplasia was considered.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!