A novel piezoelectric (PZ) immunosensor for the direct detection of malarial Plasmodium falciparum histidine rich protein-2 (PfHRP-2) antigen was developed. The mixed self-assembled monolayers (SAMs) of thioctic acid and 1-dodecanethiol were formed on gold surface of quartz crystal. Cyclic voltammetry, electrochemical impedance spectroscopy and surface Raman spectroscopy techniques were used to characterize the mixed SAMs. The rabbit anti-PfHRP-2 antibodies were coupled on mixed SAM modified gold surface of quartz crystal via NHS/EDC activation method. The PZ immunosensor was applied to detect PfHRP-2 in the linear range of 15-60 ng/ml with a detection limit of 12 ng/ml. It was also found that even after 14 days of storage, 50% of the activity still remained. Clinical human serum samples were tested with this method, and the results were in agreement with those obtained from commercially available ICT kit (NOW(®) Malaria).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2011.07.008DOI Listing

Publication Analysis

Top Keywords

novel piezoelectric
8
piezoelectric immunosensor
8
detection malarial
8
malarial plasmodium
8
plasmodium falciparum
8
falciparum histidine
8
histidine rich
8
rich protein-2
8
gold surface
8
surface quartz
8

Similar Publications

Sonogenetics is a novel antiarrhythmic mechanism.

Chaos

January 2025

School of Physics and Information Technology, Shaanxi Normal University, Xi'an 710062, China.

Arrhythmia of the heart is a dangerous and potentially fatal condition. The current widely used treatment is the implantable cardioverter defibrillator (ICD), but it is invasive and affects the patient's quality of life. The sonogenetic mechanism proposed here focuses ultrasound on a cardiac tissue, controls endogenous stretch-activated Piezo1 ion channels on the focal region's cardiomyocyte sarcolemma, and restores normal heart rhythm.

View Article and Find Full Text PDF

Weigh-in-motion (WIM) systems aim to estimate a vehicle's weight by measuring static wheel loads as it passes at highway speed over roadway-embedded sensors. Vehicle oscillations and the resulting dynamic load components are critical factors affecting measurements and limiting accuracy. As of now, a satisfactory solution has yet to be found.

View Article and Find Full Text PDF

Corrosion damage presents significant challenges to the safety and reliability of connected vehicles. However, traditional non-destructive methods often fall short when applied to complex automotive structures, such as bolted lap joints. To address this limitation, this study introduces a novel corrosion monitoring approach using Lamb wave-based weighted fusion imaging methods.

View Article and Find Full Text PDF

Development of Piezoelectric Inertial Rotary Motor for Free-Space Optical Communication Systems.

Micromachines (Basel)

December 2024

Department of Applied Mechanics, Faculty of Civil Engineering, Vilnius Gediminas Technical University, LT-10223 Vilnius, Lithuania.

This paper presents the design, development, and investigation of a novel piezoelectric inertial motor whose target application is the low Earth orbit (LEO) temperature conditions. The motor utilizes the inertial stick-slip principle, driven by the first bending mode of three piezoelectric bimorph plates, and is compact and lightweight, with a total volume of 443 cm and a mass of 28.14 g.

View Article and Find Full Text PDF

Magnetoelectric BAW and SAW Devices: A Review.

Micromachines (Basel)

December 2024

Electrical and Computer Engineering Department, Northeastern University, Boston, MA 02115, USA.

Magnetoelectric (ME) devices combining piezoelectric and magnetostrictive materials have emerged as powerful tools to miniaturize and enhance sensing and communication technologies. This paper examines recent developments in bulk acoustic wave (BAW) and surface acoustic wave (SAW) ME devices, which demonstrate unique capabilities in ultra-sensitive magnetic sensing, compact antennas, and quantum applications. Leveraging the mechanical resonance of BAW and SAW modes, ME sensors achieve the femto- to pico-Tesla sensitivity ideal for biomedical applications, while ME antennas, operating at acoustic resonance, allow significant size reduction, with high radiation gain and efficiency, which is suited for bandwidth-restricted applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!