Three nanofiltration (NF) membranes with a chlorine tolerance > or = 1 mg L-1 were applied to reduce DBPs and their precursors in swimming pool water. A lab scale plant with crossflow modules was installed in by-pass at the sand filter outlet of a swimming pool for a period of several weeks. The chlorine tolerances of the membranes SB90 and NP030 were found to be adequate for filtration under swimming pool water conditions over the given experimental period. Retention of dissolved organic carbon (DOC) and adsorbable organic halogens (AOX) were about 70% and 80% for SB90 and 50% and 40% for NP030, respectively. DOC accumulation in the pool and the expected fresh water consumption for a treatment system consisting of ultrafiltration (UF) and NF with backwash water treatment were estimated by mass balances based on the results. Mass balances were calculated also for a German public swimming pool with a conventional water treatment system (flocculation-sand filtration-chlorination) and were compared to DOC on-line measurements. Calculation of DOC mass balances for different UF-NF treatment scenarios showed that pool water quality could be improved significantly compared to the conventional treatment system.

Download full-text PDF

Source
http://dx.doi.org/10.2166/wst.2011.213DOI Listing

Publication Analysis

Top Keywords

swimming pool
20
pool water
12
treatment system
12
mass balances
12
precursors swimming
8
water quality
8
water treatment
8
pool
7
water
7