A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Three-year follow-up of the MULTIcentre evaluation of Single high-dose Bolus TiRofiban versus Abciximab with Sirolimus-eluting STEnt or Bare-Metal Stent in Acute Myocardial Infarction StudY (MULTISTRATEGY). | LitMetric

Background: The Multicentre Evaluation of Single high-dose Bolus TiRofiban versus Abciximab with Sirolimus-eluting Stent or Bare Metal Stent in Acute Myocardial Infarction Study [MULTISTRATEGY]) randomised 745 patients with ST-elevation myocardial infarction to receive high-dose bolus (HDB) tirofiban or abciximab infusion and sirolimus-eluting (SES) or uncoated-stent (BMS) implantation. Tirofiban was non-inferior to abciximab in terms of ST-segment resolution after intervention, whereas 8 month-major adverse cardiac events occurred in 14.5% in the BMS and 7.8% in the SES groups (P = 0.0039), reflecting a reduction of reintervention rates (10.2% vs. 3.2%). A three-year follow-up was performed to extend previous short- to mid-term findings.

Methods And Results: Complete data at 3 years was available for 736 patients (99%). All-cause mortality was 6.7% in the tirofiban and 7.8% in the abciximab (P = 0.56) and 7.5% in the BMS vs 7.0 in the SES groups, P = 0.79. The composite of all-cause death or MI was identical at 12.9% in tirofiban and abciximab groups, P = 0.99 and it occurred in 13.2% in the BMS vs. 12.6% in the SES groups (P = 0.83). The need for reintervention remained more than twice as common with BMS (13.7%; versus 6.2%, P = 0.0006). The cumulative rate of stent thrombosis (ST) did not differ. This is inspite of a higher very late definite, probable or possible ST thrombosis rate in the SES group.

Conclusions: The 3-year follow-up of MULTISTRATEGY demonstrated comparable outcomes with HDB Tirofiban or abciximab and a sustained efficacy of SES to reduce reintervention with no difference in death, repeat MI or ST.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2011.07.106DOI Listing

Publication Analysis

Top Keywords

high-dose bolus
12
myocardial infarction
12
tirofiban abciximab
12
ses groups
12
three-year follow-up
8
multicentre evaluation
8
evaluation single
8
single high-dose
8
bolus tirofiban
8
tirofiban versus
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!