TEE images of aorto-pulmonary (central) shunt.

Ann Card Anaesth

Department of Anaesthesiology and Intensive Care, G. B. Pant Hospital, New Delhi, India.

Published: December 2011

Download full-text PDF

Source
http://dx.doi.org/10.4103/0971-9784.84033DOI Listing

Publication Analysis

Top Keywords

tee images
4
images aorto-pulmonary
4
aorto-pulmonary central
4
central shunt
4
tee
1
aorto-pulmonary
1
central
1
shunt
1

Similar Publications

The flow convergence method includes calculation of the proximal isovelocity surface area (PISA) and is widely used to classify mitral regurgitation (MR) with echocardiography. It constitutes a primary decision factor for determination of treatment and should therefore be a robust quantification method. However, it is known for its tendency to underestimate MR and its dependence on user expertise.

View Article and Find Full Text PDF

Transesophageal echocardiography (TEE) is one of the cornerstones of cardiac imaging in inpatient and intra-operative settings. TEE is considered a safe procedure, but it may result in serious complications, such as esophageal injury, vocal cord paralysis, arrhythmia, hypotension, seizure, and cardiac arrest. Herein, we discuss one of the rare complications, esophageal perforation, and a conservative approach to managing the patient in a 64-year-old female who underwent a TEE prior to a scheduled valvular surgery.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) is a common treatment for severe aortic stenosis (AS), but it carries the risk of severe complications, including device embolization. We present a case of a TAVR valve embolization into the left ventricular outflow tract (LVOT), diagnosed with transesophageal echocardiography (TEE) shortly after device deployment. The dislodged valve was successfully retrieved from the LVOT into the aorta, flattened, and stabilized with a thoracic endovascular aneurysm repair (TEVAR) stent, enabling the successful implantation of a new TAVR valve.

View Article and Find Full Text PDF

Preclinical Experience Using 4D Intracardiac Echocardiography to Guide Cardiac Electrophysiology Procedures.

J Cardiovasc Electrophysiol

December 2024

Division of Cardiovascular Medicine, Cardiac Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.

Introduction: Intracardiac echocardiography (ICE) is an essential imaging modality for electrophysiology procedures, allowing intraprocedural monitoring, real-time catheter manipulation guidance, and visualization of complex anatomic structures. Four-dimentional (4D) ICE is the next stage in the evolution of the technology, permitting 360° rotation of the imaging plane, simultaneous multiplanar imaging, and volumetric acquisition, similar to transesophageal echocardiography (TEE). In this study, we report our experience with a novel 4D ICE catheter (NuVision, Biosense Webster) in structural electrophysiology procedures and difficult ventricular ablations in a swine preclinical model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!