Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A new molecularly imprinted polymer (MIP), selective for major metabolites of quinoxaline-1,4-dioxides was firstly prepared by combining surface molecular imprinting technique with the sol-gel process. Methyl-3-quinoxaline-2-carboxylic acid (MQCA) was used as template, 3-aminopropyltriethoxysilane as functional monomer, and tetraethoxysilicane as cross-linker. The MIP was characterized by Fourier transform infrared and evaluated through static adsorption experiments. The results indicated that MIP had high adsorption capacity, fast binding kinetics for MQCA, and the polymer showed a high degree of cross-reactivity for quinoxaline-2-carboxylic acid (QCA). The MIP was then applied as a selective sorbent in an online solid phase extraction (SPE) coupled with high-performance liquid chromatography (HPLC). For a 50-mL sample solution, enrichment factors of 1,349 and 1,046 for QCA and MQCA, respectively, and limits of detection (S/N=3) of 0.8 and 2 ng L(-1) for QCA and MQCA, respectively, were obtained (corresponding to 0.02 and 0.04 ng g(-1) in solid samples for final 100 mL of sample solutions of 5 g of pork). The sample preparation protocol was simplified and only included one step extraction with acetonitrile (MeCN) after the release of target analytes through acidic hydrolysis without further sample cleanup. The new MIP-SPE-HPLC method was successfully applied to the quantification of trace QCA and MQCA in pork muscle with good recoveries ranging from 67% to 80% and RSD below 8%.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00216-011-5329-0 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!