Study Design: A cadaveric biomechanical experiment was conducted to assess the range of motion (ROM) and screw strain at S1 in a long instrumented spinal fusion construct to compare the effects of various surgical strategies for L5-S1 stabilization.

Objective: To directly quantify and compare S1 screw strains and lumbosacral ROM for 4 different L2-S1 posterior segmental instrumented fusion constructs: an L2-S1 pedicle screw (PS) construct alone and PS with each of 3 different augmentations, anterior lumbar intebody fusion (ALIF), anterior axial interbody threaded rod (AxiaLITR), or iliac screws.

Summary Of Background Data: Iliac screws and anterior interbody devices are commonly used as augmentation to reduce the incidence of S1 screw loosening in long fusion constructs. Alternatives, such as AxiaLITR, may provide similar biomechanical advantages without many of the same long-term limitations and morbidities.

Methods: Pure moment flexibility testing was performed in 6 cadaveric lumbosacral spines. Specimens were tested with 4 instrumentation constructs: (1) PS L2-S1, (2) PS with ALIF, (3) PS with AxiaLITR, and (4) PS with iliac screws. Bilateral S1 PS were instrumented with strain gauges, directly measuring screw loading while simultaneously measuring L5-S1 ROM with a noncontact camera system.

Results: Average S1 screw strains were the greatest with the PS group and were reduced by 38% with the ALIF group, 75% with the AxiaLITR group, and 78% with the iliac screw group in flexion-extension (P < 0.05). Similar trends were observed in torsion (P < 0.05). Strains in lateral bending were smaller in magnitude and were similar among all 4 constructs. The AxiaLITR and iliac screw groups demonstrated a similar ROM and significant reduction in ROM at L5-S1 compared with both the PS and ALIF groups (P ≤ 0.02 and P < 0.03).

Conclusion: The results of this study indicated that iliac screws and AxiaLITR provide similar stability at L5-S1, while significantly reducing the strain on the S1 screws.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BRS.0b013e31822ce9a7DOI Listing

Publication Analysis

Top Keywords

screw strains
12
axialitr iliac
12
iliac screws
12
screw
10
sacral screw
8
screw strain
8
range motion
8
fusion constructs
8
constructs l2-s1
8
axialitr provide
8

Similar Publications

Some one-dimensional (1D) crystals containing a screw dislocation along their longer axis exhibit a helical twist due to lattice strain. These chiral structures have been thoroughly investigated by using transmission electron microscopy. However, whether two-dimensional (2D) crystals with a spiral surface pattern, presumably containing a screw dislocation, are structurally chiral remains unclear because their internal structures are not visible.

View Article and Find Full Text PDF

Before patients begin out-of-bed exercises following internal fixation surgery for acetabular fractures, turning over in bed serves as a crucial intervention to mitigate complications associated with prolonged bed rest. However, data on the safety of this maneuver post-surgery are limited, and the biomechanical evidence remains unclear. This study aims to introduce a novel loading protocol designed to preliminarily simulate the action of turning over in bed and to compare the biomechanical properties of two fixation methods for acetabular fractures under this new protocol.

View Article and Find Full Text PDF

Characterizing threading dislocations (TDs) in gallium nitride (GaN) semiconductors is crucial for ensuring the reliability of semiconductor devices. The current research addresses this issue by combining two techniques using a scanning electron microscope, namely electron channeling contrast imaging (ECCI) and high-resolution electron backscattered diffraction (HR-EBSD). It is a comparative study of these techniques to underscore how they perform in the evaluation of TD densities in GaN epitaxial layers.

View Article and Find Full Text PDF

A Novel Dynamic Growth Rod Inducing Spinal Growth Modulation for the Correction of Spinal Deformities.

JOR Spine

March 2025

Beijing Key Laboratory for Design and Evaluation Technology of Advanced Implantable & Interventional Medical Devices, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering Beihang University Beijing China.

Background: Growth rods are the gold standard for treating early-onset scoliosis (EOS). However, current treatments with growth rods do not optimize spinal growth in EOS patients, and frequent distraction surgeries significantly increase complications, imposing considerable economic and psychological burdens on patients. An improved growth rod is urgently required to address the need for dynamic growth and external regulation.

View Article and Find Full Text PDF

Finite element investigation for improving chest wall reconstruction process using ceramic and polymeric implants.

Sci Rep

January 2025

Biomedical Engineering Department, Faculty of Engineering, Helwan University, Cairo, Egypt.

Car accidents, infections caused by bacteria or viruses, metastatic lesions, tumors, and malignancies are the most frequent causes of chest wall damage, leading to the removal of the affected area. After excision, artificial bone or synthetic materials are used in chest wall reconstruction to restore the skeletal structure of the chest. Chest implants have traditionally been made from metallic materials like titanium alloys due to their biocompatibility and durability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!