Purpose: To describe the transition to digital imaging and assess any impact on ocular disease classification.

Methods: Film and digital images, acquired by certified photographers, were evaluated independently according to standard procedures for the following: image quality, presence of cytomegalovirus retinitis lesions, and their extent and proximity from disk and macula. Intergrader agreement within the digital medium was also assessed.

Results: Among the 15 eyes with cytomegalovirus retinitis, the mean difference between film and digital images for linear distance of lesion edge to disk was 0.02 disk diameters, for distance to center of macula was -0.04 disk diameters, and area covered by cytomegalovirus retinitis was 0.95 disk area. There was no statistically significant difference in distance and area measurements between media. Intergrader agreement in measurements of digital images was excellent for distance and area estimated.

Conclusion: Our results suggest that digital grading of cytomegalovirus retinitis in Longitudinal Studies of the Ocular Complications of AIDS is comparable with that from film regarding disease classification, measurements, and reproducibility. These findings provide support for continuity of grading data, despite the necessary transition in imaging media.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4164651PMC
http://dx.doi.org/10.1097/IAE.0b013e318221592fDOI Listing

Publication Analysis

Top Keywords

cytomegalovirus retinitis
16
film digital
12
digital images
12
longitudinal studies
8
studies ocular
8
ocular complications
8
complications aids
8
intergrader agreement
8
disk diameters
8
distance area
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!