A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A quantitative LC-MS/MS method for comparative analysis of capture-antibody affinity toward protein antigens. | LitMetric

A quantitative LC-MS/MS method for comparative analysis of capture-antibody affinity toward protein antigens.

J Chromatogr B Analyt Technol Biomed Life Sci

Analytical Chemistry Division, National Institute of Standards and Technology, 100 Bureau Drive, Stop 8392, Gaithersburg, MD 20899-8392, USA.

Published: September 2011

A mass spectrometry-based antibody selection procedure was developed to evaluate optimal 'capture' monoclonal antibodies that can be used in a variety of analytical measurement applications. The isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) methodology is based on the use of multiple-reaction monitoring of tryptic peptide fragments derived from protein antigens. A panel of monoclonal antibodies (mAb) was evaluated based on a quantitative determination of relative binding affinity to human cardiac troponin I following immunoprecipitation. Dissociation constants (K(d)) were determined for 'bound mAb-antigen' vs. 'unbound antigen' using non-linear regression analysis. Relative quantification of both antigen and antibody was based on the use of stable isotope-labeled synthetic peptides as internal standards. Optimal 'capture' mAbs were determined through evaluation of relative K(d) constants of all monitored peptide transitions. A panel of six pre-screened candidate capture mAbs was concluded to consist of two subsets of mAbs, each with statistically equivalent K(d) constants as determined using NIST Standard Reference Material (SRM) 2921 - Human Cardiac Troponin Complex. This ID LC-MS/MS method is shown to be capable of quantitatively differentiating mAbs based on relative binding affinities. Selection of optimal capture mAbs can be applied toward a number of analytical applications which require metrological traceability and unbiased quantification.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2011.07.037DOI Listing

Publication Analysis

Top Keywords

lc-ms/ms method
8
protein antigens
8
optimal 'capture'
8
monoclonal antibodies
8
relative binding
8
human cardiac
8
cardiac troponin
8
constants determined
8
capture mabs
8
mabs
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!