A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Highly sensitive pyrosequencing system with polymer-supported enzymes for high-throughput DNA analysis. | LitMetric

Highly sensitive pyrosequencing system with polymer-supported enzymes for high-throughput DNA analysis.

Anal Chem

Central Research Laboratory, Hitachi, Ltd., 1-280, Higachi-koigakubo Kokubunji-shi, Tokyo, Japan.

Published: October 2011

AI Article Synopsis

  • A new pyrosequencing system utilizes a gel matrix to achieve high-density enzyme immobilization in microreaction chambers, enhancing sensitivity.
  • Reducing the size of these chambers is crucial for high throughput, enabling efficient detection using minimal photopixels.
  • The innovative approach increases luminescence intensity by allowing higher luciferase concentrations, resulting in smaller DNA beads (6.5 μm chambers and 4 μm beads) that facilitate inexpensive, efficient pyrosequencing.

Article Abstract

A highly sensitive massively parallel pyrosequencing system employing a gel matrix to immobilize enzymes at high density in microreaction chambers is demonstrated. Reducing the size of microreaction chambers in a DNA analyzer is important to achieve a high throughput utilizing a commercially available detection device or camera. A high-performance system can be attained by detecting signals from one reaction chamber with one photopixel of around several micrometers by utilizing a 1:1 image magnification. However, the use of small beads immobilizing DNA has a disadvantage in detecting luminescence because only small amounts of DNA can be immobilized on the bead surfaces for sequencing. As luminescence intensity could be enhanced by increasing the luciferase density in the chambers, we overcame this difficulty by using a gel matrix to immobilize luciferase at a high concentration in the microreaction chambers. Luminescence 1 order of magnitude higher could be observed with the new method compared to the conventional method. Consequently, the chamber size and bead size immobilizing DNA could be reduced to as small as 6.5 and 4 μm, respectively. This can be successfully applied to achieving small, inexpensive, pyrosequencing systems with high throughput.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac201357tDOI Listing

Publication Analysis

Top Keywords

microreaction chambers
12
highly sensitive
8
pyrosequencing system
8
gel matrix
8
matrix immobilize
8
high throughput
8
immobilizing dna
8
dna
5
sensitive pyrosequencing
4
system polymer-supported
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!