Venous gas emboli (VGE) can be readily detected in the bloodstream using existing ultrasound methods. No method currently exists to detect decompression-induced microbubbles in tissue. We hypothesized that dual-frequency ultrasound (DFU) could detect these microbubbles. With DFU, microbubbles are driven with two frequencies: a lower "pump" (set to the resonant frequency of the desired bubble size) and a higher "image" frequency. A bubble of the resonant size emits the sum and difference of the two transmitted frequencies. For this study we used a pump frequency of 2.25 MHz and an image frequency of 5.0 MHz, which detects bubbles of roughly 1-10 μm in diameter in a water tank. Four anesthetized swine were pressurized at 4.5 ATA for 2 h and decompressed over 5 min, inducing moderate to very severe VGE scores. Four sites on the thigh of each swine were monitored with DFU before and after the dives. A single mock dive was also performed. The number of sites returning signals consistent with microbubbles increased dramatically after the chamber dive (P < 0.01), but did not change with the mock dive. The increase in DFU signal after the chamber dive was sustained and present at multiple sites in multiple swine. This research shows for the first time that decompression-induced tissue microbubbles can be detected using DFU and that DFU could be used to monitor decompression-induced microbubbles at multiple sites on the body. Additionally, DFU could be used to track the time course of microbubble formation and growth during decompression stress.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/japplphysiol.01203.2010 | DOI Listing |
Ultrason Sonochem
January 2025
School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300350, China; Tianjin Key Laboratory of Chemical process safety and equipment technology, Tianjin 300350, China. Electronic address:
Ultrasonic reactors, widely applied in process intensification, face limitations in their industrial application due to a lack of theoretical support for their structural design and optimization, particularly concerning the uniformity of the cavitation zone. Addressing this gap, our study introduces a novel approach to design a multi-frequency octagonal ultrasonic reactor of capacity 9.5 L through numerical simulation and spectrum analysis.
View Article and Find Full Text PDFJ Cosmet Dermatol
November 2024
Wellcomet GmbH, Bruchsal, Germany.
Objectives: Earlier, quickly alternating dual-frequency ultrasound waves (LDM technology) were successfully applied for the treatment of different inflammatory skin conditions such as rosacea and acne. In this retrospective pragmatic two-center clinical study, we applied the triple-frequency LDM (TF-LDM) technology with frequencies of 1/3/10 and 3/10/19 MHz for the treatment of mild-to-severe acne skin to assess the effectivity and sustainability of the treatment outcomes.
Methods: Twenty-two patients with mild-to-severe acne were included in this study: 11 patients were treated with TF-LDM (1/3/10 MHz), and other 11 patients-with TF-LDM (3/10/19 MHz).
Ultrasonics
February 2025
School of Information Science and Technology, Fudan University, Shanghai 200433, China.
In Lamb wave imaging based on a phased array, higher frequencies narrowband excitation pulses enable more precise damage detection and localization. However, due to the size constraints of individual transducer elements, the spacing between array elements may exceed half the wavelength of the excitation signal. This can lead to a grating lobe effect.
View Article and Find Full Text PDFUltrason Sonochem
December 2024
Food Refrigeration and Computerized Food Technology (FRCFT), Agriculture and Food Science Centre, University College Dublin, National University of Ireland, Belfield, Dublin 4, Ireland.
Faba bean proteins are currently viewed as promising animal protein alternatives. However, certain functional properties e.g.
View Article and Find Full Text PDFUltrason Sonochem
December 2024
School of Food and Biological Engineering, Jiangsu University, 212013 Zhenjiang, Jiangsu, China. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!