Objective: To develop a new, custom-made pressure device that can be used with established designs as an adjuvant therapy for optimized treatment of auricular keloids.
Methods: Seven patients (4 males, 3 females; mean [SD] age, 22.6 [8.3] years) were treated with surgical excision and corticosteroid injection followed by application of our new auricular pressure device.
Results: All patients tolerated the adjuvant therapy and wore the device overnight for 5 nights per week. Usage was not interrupted or cancelled. No recurrence was observed during the follow-up period (mean [SD] duration of follow-up, 24 [6] months). All patients were satisfied with the results; none described pruritus, pain, or dysesthesia.
Conclusion: Overnight usage of the new pressure device seems to be a safe and effective extension of established auricular keloid therapy with the potential for prophylaxis of recurrence.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1001/archfacial.2011.57 | DOI Listing |
Biosens Bioelectron
January 2025
Department of Physics, Virginia Commonwealth University, Richmond, VA, 23284, USA; Institute for Sustainable Energy and Environment, Virginia Commonwealth University, Richmond, VA, 23284, USA. Electronic address:
Wearable devices designed for the somatosensory system aim to provide event-cue feedback electronics and therapeutic stimulation to the peripheral nervous system. This prompts a neurological response that is relayed back to the central nervous system. Unlike virtual reality tools, these devices precisely target peripheral mechanoreceptors by administering specific stimuli.
View Article and Find Full Text PDFAnn Plast Surg
February 2025
From the Department of Plastic and Reconstructive Surgery, Ewha Womans University College of Medicine, Mokdong Hospital, Seoul, Republic of Korea.
Indocyanine green (ICG) is a water-soluble green substance that is detectable through infrared cameras and emits greenish light. Approved for medical use in the 1950s, ICG has gained prominence as a real-time visualization tool. Widely recognized as a generally safe substance, ICG is applied in diverse fields.
View Article and Find Full Text PDFPLoS One
January 2025
School of Mechanics and Engineering, Liaoning Technical University, Fuxin, Liaoning, China.
Using the Ordos Basin dry sandstone and sandstone saturated with different saline concentrations as research subjects, a self-developed constant temperature and pressure CO2 injection simulation device was employed to conduct permeability tests on sandstone under varying effective stresses and CO2 injection pressures. The test results indicated that during the CO2 injection process, the permeability of dry sandstone was two orders of magnitude higher than that of sandstones saturated with different saline concentrations. When the effective stress increases from 10 MPa to 28 MPa, the fissure compressibility of reservoir sandstone is influenced by the saturation of different saline concentrations, with the compressibility coefficients for 0%, 15%, and 30% saline-saturated sandstone being 0.
View Article and Find Full Text PDFJMIR Res Protoc
January 2025
Clinical Physiology Institute, Consiglio Nazionale delle Ricerche, Pisa, Italy.
Background: Among cardiovascular diseases, adult patients with congenital heart disease represent a population that has been continuously increasing, which is mainly due to improvement of the pathophysiological framing, including the development of surgical and reanimation techniques. However, approximately 20% of these patients will require surgery in adulthood and 40% of these cases will necessitate reintervention for residual defects or sequelae of childhood surgery. In this field, cardiac rehabilitation (CR) in the postsurgical phase has an important impact on the patient by improving psychophysical and clinical recovery in reducing fatigue and dyspnea to ultimately increase survival.
View Article and Find Full Text PDFJ Glaucoma
January 2025
Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore.
Purpose: Trabecular micro-bypass devices (TBDs) such as the iStent series (Glaukos Corporation, Laguna Hills, CA), are effective in reducing intraocular pressure (IOP). However, precise placement of TBDs is crucial in achieving surgical efficacy, as device malpositioning may lead to suboptimal IOP reduction. We demonstrate two novel intra-operative signs to aid confirmation of accurate iStent placement, without reliance on imaging technologies.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!